USE AND OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
TEMPERATURE / TIMER SET CONTROLS
•
Used for adjusting the timer and thermostat.
•
The default display is setting temperature.
In cooling mode, when ▼ or ▲ button is pressed, the set temperature is displayed and may be
•
adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only
adjustable in cool mode. The time is adjustable between 1 - 24 hours.
Note: By pressing both ▼ or ▲ buttons at the same time, the display will toggle between
Celsius(°C) and Fahrenheit(°F).
FAN SPEED CONTROL
3 settings: High, Medium and Low.
TIMER CONTROL
While the unit is turned on, press the timer button then press the ▼ or ▲ to select the number of
hours you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the ▼ or ▲ button to select the number of hours you want the unit to run
in air conditioning mode.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the ▼ or ▲ button to
select the number of hours until you want the unit to automatically start running.
EN
9