Installing the Unit
1. Cut the appropriate opening in the countertop for the unit
being installed (see below).
344 mm
(13-9/16")
RCTHW-6B Countertop Cutout Dimensions
NOTE: The countertop must be level to ensure proper draining
of the well.
NOTICE
Remote mounted control boxes must have a minimum
152 mm (6") clearance from unit (not to exceed 1420
mm [56"]). Mounting control box closer may cause heat
damage to electrical system in control box.
The remote mounted control box should be installed
outside of heat zone. Locating the control box inside heat
zone will cause the control(s) to overheat, malfunction,
and fail.
2. Cut the appropriate opening for the control box in a vertical
surface at least 152 mm (6") from the unit, but no more
than 1420 mm (56") (see below).
33 mm
(1-5/16")
65 mm
(2-9/16")
Ø 4,5 mm
(3/16")
Control Box Cutout Dimensions
NOTE: The electrical cord between the unit and the control box
is 1420 mm (56") in length.
3. Place ribbon putty gasket around the cutout edge of the
countertop. Make sure the ribbon putty gasket overhangs
the cutout edge or seal unit with silicone adhesive.
4. Guide the control box and electrical cords through the
countertop cutout, and lower the unit into the cutout.
Form No. RCTHW6CEM-1017
570 mm
(22-1/2")
144 mm
(5-9/16")
132 mm
(5-1/8")
154 mm
(6")
Control Box
Cutout
Installing the Unit
5. Assemble the L-brackets to the
underside of the unit.
6. Tighten the L-bracket screws until
the mounting plate lies flat on the
countertop.
NOTICE
Do not use excessive force when
tightening mounting screws on
built-in units. This may damage unit
and/or countertop.
Installing the Remote-Mounted Control Box
1. Install the control box in the control box cutout:
a. Remove the four screws that secure the front cover
to the control box. Remove the front cover and pass it
through the cutout to the front of the installation surface.
b. Pass one of the mounting flanges on the control box
housing through the cutout. Squeeze the other mounting
flange to fit it through the cutout.
c. Align the holes on the
mounting flanges with
the screw holes in the
installation surface, and
secure the control box
housing to the surface
using four M4 screws
(not supplied).
d. Install the front cover
on the control box using
the four front cover
screws.
2. Have a qualified electrician perform the necessary
electrical connections (refer to "Electrical Connections" in
this section for additional information).
7
INSTALLATION
Mounting
Plate
Countertop
Cutout
Countertop
Mounting
Plate
Screw
L Bracket
Control Box
Housing
Mounting
Flange
Front
Cover