Descargar Imprimir esta página

Rangemaster RM53000 Serie Manual De Instrucciones página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARE THE HOOD (CONT'D)
(NON=DUCTED HOODS ONLY)
8. Carefully slide the upper decorative flue down
inside the lower flue.
9. Carefully place the decorative flues into the
recessed area d the range hood top.
Note: Air vents must be up.
ROOMS WITH 10=FO0 T CEILINGS
Rooms with 10-Foot
ceilings require flue
extension
model
RFXN5304,
available from your local dealer.
4 FLAT HEAD
SCREWS
UPPER FLUE
10. Discard upper flue supplied with
product. Replace with flue ex-
tension RFXN5304.
11. Secure the recirculation plenum
to the upper flue with (4) flat head
screws.
MOUNTING
SCREWS
(4,8 x 38mm)
INSTALL
THE HOOD
Note: At least two people will be
required to mount the hood.
1. Align the rectangular opening on the back
of the hood with the walt-mounting bracket.
Gently lower the hood until it securely en-
gages the bracket.
2. Level the hood and secure with (2) mount-
ing screws under the hood. Use drywall
anchors provided if wall studs or framing
are not available.
3. Raise the upper flue until its holes align
with holes in the flue mounting bracket (lo-
cated on ceiling).
4. Secure the flue with (2) mounting screws.
MOUNTING
BRACKET
RECTANGULAR
CUTOUT
3.9 x 9,Smm
MOUNTING SCREWS