INSTALL
THE DUCTWORK
(DUCTED
HOODS ONLY)
A
CAUTION: To reduce the risk of fire, use
only metal ductwork.
1. Decide where the ductwork will run be-
tween the hood and the outside.
2. A straight, short duct run will allow the hood
to perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use as
few of them as possible. Larger ducting may
be required for best performance with longer
duct runs.
4. Install a rooforwalt cap. Connect round metal
ductwork to cap and work back towards hood
location. Use duct tape to seat the joints be-
tween ductwork sections.
ROOF CAP
N
6"
ROUND
DUCT
DECORATIVE:
24" TO 30" ABOVE
COOKING
SURFACE
See "INSTALL
MOUNTING
BRACKET"
section
for
mounting
restrictions)
ROUND
ELBOW
6"
ADAPTER
INSTALL
ELECTRICAL
_, WARNING: Electrical wiring
must be
done by a qualified
person(s)
in actor=
dance with all applicable
codes and stan=
dards.
This range hood must be prop=
edy grounded.
Turn off electrical
power
at service
entrance before wiring.
1. Plan where the hood will be located above
the cooktop. Refer to the"INSTALL MOU N-r-
ING BRACKET" section for hood mounting
height options.
2. Install a standard 2" x 4" wall outlet box and
3-blade 125 volt, 15Amp grounded recep-
tacle.
3. Mount the receptacle 18" to 22" above the
bottom of the hood.
4. Locate the receptacle within boundary shown
and off center of the ductwork (to allow for
power cord plug and flue clearance).
CENTER
LINE
OF HOOD
AND
DUCT
-8-