Descargar Imprimir esta página

LG DLEX8500 Serie Manual Del Propietário página 21

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
INSTRUCTIONS
21
Venting
requirement
Ductwork
Recommended
(10.2 cm)
(10.2 cm)
Use Only for Short
Run Installations
(6.35 cm)
0
I
2
3
4
0
I
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (I 1.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
1/
@ NOTE
.... -,
Deduct
6 ft. (I .8 m) for each additional
elbow. It is not recommended
I
to use more than four 90 ° elbows.
ROUTINGAND CONNECTINGDUCTWORK
@ NOTE
Follow the guidelines
below to maximize
drying
performance
and
reduce lint buildup
and condensation
in the ductwork.
Ductwork
and fittings
are NOT included
and must be purchased
separately.
. Use 4-inch (10.2 cm) diameter
rigid or semirigid
metal ductwork.
. The exhaust
duct run should
be as short as possible.
. Use as few elbow joints as possible.
. The male end of each section of exhaust duct must point away from
the dryer.
. Use duct tape on all duct joints.
. Insulate ductwork
that runs through
unheated
areas in order to
reduce condensation
and lint buildup
on duct surfaces.
° Failure to exhaust the dryer correctly
will void the dryer's warranty.
J
CORRECT
VENTING
!i!
.................
C
I
,,
t,
INCORRECTVENTING

Publicidad

loading

Este manual también es adecuado para:

Dlgx8501 serieDlex8500v