(2) Installing the gas hob
This appliance should be installed by a registered Gas Safe Engineer!
Gas connection
The gas connection must be located in position where the stop tap is accessible.
The end of the inlet connection point of the gas hob has a 1/2" thread that allows for:
• A fixed connection
• Connection using a flexible pipe (L min. 1 m - max. 3 m)
The watertight seal supplied must be inserted between the manifold outlet and the gas
supply. You must prevent the pipe from coming into contact with moving parts of the
kitchen unit (for example, a drawer) and prevent access to any spaces which might
become obstructed.
CAUTION
Danger of leaks! If any connection is handled, check the seal.
The manufacturer is not liable for any connection leaking, after being
handled.
Do not use too much force when
tightening; Otherwise, it will
cause elbow fracture or rubber
ring deformation and leakage.
Note that the torque wrench must
be used to tighten with a torque
of 10 Nm. The maximum torque
cannot exceed 20 Nm.
EN
41