Before performing any maintenance, disconnect the ap-
pliance from the mains.
Regular maintenance is required for the stove to function
correctly.
Any problems resulting from lack of maintenance will im-
mediately void the warranty.
DAILY MAINTENANCE
Operations must be performed when the stove is off, cold
and unplugged from the power supply
• Cleaning must be carried out with a vacuum cleaner. (see
optional extras page 48).
• Open the door, remove the ash grill (1 - Fig. A) and pour the
residue into the ash tray (2 - Fig. B).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PEL-
LET HOPPER.
• Pull the ash drawer (2 - g. b) out and empty it into a non-
ammable container (the ash may still have some parts that are
hot and/or embers).
• Vacuum the inside of the combustion chamber, the re sur-
face, and the compartment around the ash grill where the ash
falls.
• Remove the ash grill (1 - Fig. A) and remove encrustations
with the spatula provided; clean any debris clogging the holes.
• Vacuum the ash grill compartment, clean the edges where the
ash grill comes into contact with its seat.
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner
breakdown and represents a re risk.
We remind you that using the stove without cleaning the
melting pot, may cause a sudden ignition gas inside the
combustion chamber with the consequent breaking of the
glass.
ATTENTION:
MAKE SURE THE ASH TRAY IS CORRECTLY POSI-
TIONED IN ITS HOUSING
WEEKLY MAINTENANCE
• Clean the combustion chamber (with brush).
• Vacuum the hose located near the electrical resistance (3 -
Fig. C).
• Clean the combustion chamber.

MAINTENANCE

g. A
g. B
g. C
- 43
-