THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Yield / Ef ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Hopper capacity
Draught
Autonomy
Heatable volume *
Smoke outlet pipe diameter (female)
Air intake pipe diameter (male)
Weight including packaging (glass-soapstone)
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume ow capacity

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply* (see page 30)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS of at
least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi cation on the part of the noti ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES (burning pellets)
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insuf cient for it to function correctly.
• HEARTH SAFETY MICROSWITCH:
A buzzer controlled by a microswitch on the door of the combustion chamber warns if the door is not properly closed.
GENERAL INFORMATION
PELLET
Nominal power
10
90
18
135
2,3
18
PELLET
Nominal power
10
162
8,3
EN 14785 (pellet) - EN 13240 (wood)
according to
Reduced power
Nominal power
3
91,4
85,8
149
1072
65
0,7
45
12 - 5
60
260
150
80
292 - 295
Reduced power
Nominal power
3
78
0 - 5
5,6
230Vac +/- 10% 50 Hz
Yes
130 W
320 W
onderadio 2,4 GHz
T2A, 250 Vac, 5x20 Fuse
T2A, 250 Vac, 5x20 Fuse
- 32
-
WOOD
Reduced power
10
5
84,3
2094
208
188
2,5
1,3
-
12 - 6
-
WOOD
Reduced power
10
5
250
225
0 - 5
7,7
4,5
kW
%
3
mg/m
°C
kg/h
kg
Pa
hours
3
m
mm
mm
kg
kW
°C
Pa
g/s