MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a SEASONAL basis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
DAILY MAINTENANCE
Operations must be performed when the stove is off, cold and unplugged from the power supply
Cleaning must be carried out with a vacuum cleaner. (see optional extras page 63).
The whole procedure takes up a few minutes every day.
Shake the cleaning rods often (when cold) – these are found in the front upper part (*).
*
*
**
1
2
2
• Open the door and remove and empty the ash pan (**).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides.
• Remove the combustion chamber (1) and scrape with a spatula. Clean any obstructions in the apertures.
• Suction the combustion chamber holder, clean the contact edges and remove the smoke caps (2).
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fire
WEEKLY MAINTENANCE
• Clean the hearth (with a brush) after having removed the 2 smoke deviators (3).
• empty the hopper and vacuum the base when the stove has not been used for a period of time and when used, once every 15 days.
• When cleaning the combustion chamber, lift the smoke caps (2) and suction the four pipes underneath (4).
4
4
3
2
3
2
NOTE: After every 800 kg, "Mainten." will appear to remind the user to clean the smoke channels, which is the
user's responsibility. This message will disappear by pressing the "TURBO" button for 5 seconds. Upon rea-
ching 2000 kg of pellets, a "Mainten.-dealer" message will appear which will not disappear because the assistan-
ce of a DEALER is required. This message can be reset from the parameters menu.
61