For more information, please refer to the Sensepoint App manual.
When a Bluetooth® connection is established, the detector's reading is displayed on the app interface with the gas type
and other information.
12
Specifications
Physical specification
Dimension
Weight
Power supply
DC input voltage (nominal)
AC input voltage (nominal)
Inrush current
Maximum power consumption
mA Versions
Modbus versions
Relay versions
Outputs
§
Analog output
Digital output
Relay output
Operating Environment
Operating temperature
Storage temperature
Humidity
Atmospheric pressure
Ingress protection
Installation category
Pollution degree
Cable Gland
Inner knock-out
Outer knock-out
Gas Test Tubing
Inner diameter
Outer diameter
mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC
†
20 to 27 VAC
‡
Dependent on version
§
Flammable catalytic versions: 10 to 90% RH. Operating the detector outside of this range may result drift and a
¶
decrease detector accuracy.
© 2017 Honeywell Analytics
113 mm × 113 mm × 59 mm (4.4 × 4.4 × 2.3 in)
500 g (1.1 lb)
24 V DC†
24 V AC‡, 50/60 Hz
Less than 850 mA
< 1.2 W (toxic), < 1.7 W (flammable)
< 0.7 W (toxic), < 1.2 W (flammable)
Additional 0.6 W
0 to 22 mA sink or source (configurable)
Modbus RTU
2 × dry contact relays for fault and alarm signalling. Rated at 5 A @ 24 V DC, 5 A @ 240 V AC
−20 to 50°C (−4 to 122 °F)
0 to 30°C (32 to 86 °F)
0 to 99% (non-condensing)
¶
90 to 110 kPa
IP65 / Type 4 (in accordance with NEMA 250)
II (UL/CSA/IEC/EN 61010-1)
2 (UL/CSA/IEC/EN 61010-1)
M20 or ½ NPT
M25 or ¾ NPT
4 or 6 mm
6 or 8 mm
4
4