iNSTALL THE HOOD (Non-Ducted
Hoods Only - Steps 3 thru 8)
NON=DUCT
KiT MODEL
RKE59
CONTENTS
NON-DUCT PLENUM
ASSEMBLY
4 MOUNTING
SCREWS
(.188"x .375"
CrossRecessed
Flat
Head)
4 MOUNTING
(_
SCREWS
(3mm x 10mm
Cross Recessed
Pan Head)
4 FOAM
RECTANGLES
FILTER TRAY
FLEXIBLE DUCT
NON-DUCTED
RECIRCULATION
FILTERS
NOTE
Non-ducted installations require Non-Duct Kit, Model RKE59
(purchase separately).
®
4_
@
3.
Disassemble the frame by removing (8) screws. Set aside
screws and lower frame assembly.
4.
Align upper frame assembly to ceiling framing, and attach
to ceiling framing with (6) 4mm x 50mm screws. Tighten
securely, making sure that the upper frame bracket is tight
against the ceiling.
5.
Install non-duct plenum to upper frame bracket using (4)
3mm x 10mm screws.
6.
Feed house wiring around front of non-duct plenum.
7.
J
j-
LENGTH
Determine length %:' of frame assembly based upon desired
installation height. See chart on page 4. Slide lower frame
over upper frame and attach with (8) screws previously set
aside.