Compatibility
When making connections to the SRL, eliminate
all possibility of roll-out. Roll-out occurs when
interference between a connector and the
attachment point causes the connector gate to
unintentionally open and release.
All connections must be selected and deemed
compatible with the SRL by a Competent Person.
All connector gates must be self-closing, self-locking,
and withstand a minimum load of 3,600 lb (16 kN).
See Diagram B on page 7.
Limitations
Fall Clearance: There must be sufficient
clearance below the work surface to arrest a
fall before the user strikes the ground or an
obstruction. When calculating fall clearance,
account for a MINIMUM 2 ft (0,6 m) safety factor,
deceleration distance, user height, length of
lanyard/SRL, harness stretch, free fall, and all
other applicable factors.
See Diagram A on page 7.
Swing Falls: Prior to installation or use, make
considerations for eliminating or minimizing all
swing fall hazards. Swing falls occur when the
anchor is not directly above the location where
a fall occurs. Always work as close to in line
with the anchor point as possible. Swing falls
significantly increase the likelihood of serious
injury or death in the event of a fall.
Maintenance, Cleaning, and Storage
Cleaning after use is important for maintaining the
safety and longevity of the SRL. Remove all dirt,
corrosives, and contaminants from the SRL before
and after each use. If SRL cannot be cleaned with
plain water, use mild soap and water, then rinse
and wipe dry. NEVER clean SRL with corrosive
substances.
When not in use or during transport, store
equipment where it will not be affected by heat,
light, excessive moisture, chemicals, or other
degrading elements.
 WARNING!
following warnings and specifications
when using Class 2 SRLs.
Class 2 SRLs are tested and certified for
horizontal use over a steel edge without
burrs. Class 2 SRLs may be used over similar
surfaces, such as metal sheeting or other
steel formations.
The allowable angle of redirection of the
lifeline portion of Class 2 SRLs at the leading
edge of a fall hazard MUST be at least 90°
(see Diagram C).
Anchor point MUST be situated no lower than
the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST
calculate adequate fall clearance (see pg. 2).
Setback distance: As determined by product
testing, Guardian Class 2 SRLs are not
required to be setback any specific distance
from the leading edge of applicable fall
hazard(s).
Class 2 SRLs may be used in combination
with horizontal lifelines. All installation, set-up,
and use of horizontal lifelines must be done
under the supervision of a Qualified Person.
NEVER work on the far side of an opening
that is opposite the Class 2 SRL anchorage
point.
In the event of a fall over the edge, special
rescue measures may be necessary.
Always account for use of Class 2 SRLs in
job site rescue plan developed by job site
Competent Person.
3