3.
SPECIFICATIONS
Measuring ranges
Scaling factor
Output sensitivity
Accuracy (45-65Hz)
Noise
Output Connector
Power Supply
Battery Life (typ.)
external
Connector Barrel plug socket 5,5/2,1mm
Output load
Frequency range
Phase angle error
Position sensitivity
External field
Temperature coeff.
Low battery
Overload
_______________________________________________________________
METRAFLEX 3000M
30A
10
100mV/A 10mV/A
±1% of rdg.
±0.2A
3mVrms 1mVrms 0.1mVrms 1.5mVrms 0.5mVrms 0.05mVrms
1 pair 4mm safety plugs
Battery
2x AA MN1500 LR6 Alkaline
150 hrs (M'FLEX 3000M)
3,5...12VDC/max. 100mA
minus at center pin
≥100 kΩ for specified accuracy
20 Hz to 100 kHz (-20% attenuation)
<±1° (45-65Hz)
±2.5% of reading
±0.2% of range with cable >100mm
(4") from the probe
±0.15% / ° K
Indicated by an orange LED
Indicated by a red LED
300A
3000A
100
1000
1mV/A
±1% of rdg.
±1A
METRAFLEX 3000MXL
30A
300A
20
200
50mV/A
5mV/A
±1% of rdg.
±0.2A
4 pin Hypertronics plug
2x AA MN1500 LR6 Alkaline
150 hrs (M'FLEX 3000MXL)
2...3VDC/max. 100mA
Barrel plug socket 5,5/2,1mm
minus at center pin
3000A
2000
0,5mV/A
±1% of rdg.
±1A
7