Ensure the shutter arm (v) is located into the shutter
slot when the External grille is fitted. Finally check for
correct running and shutter operation.
Wall mounting (extended fixing rod set accessory must
be used)
• Cut a hole in the wall where the unit is to be mounted,
in accordance with the dimensions indicated in Fig. A.
It is recommended that this should be a minimum of
1500mm from ground level.
• Measure the thickness of the wall and cut the threaded
rods (n) 5 mm shorter than this thickness.
• Use the appliance to mark on the wall the position of
the fixing holes for the support plate (f), drill the fixing
holes and insert the wall plugs.
Dismantle the HV-fan in accordance with the following
instructions:
Fig. 10 Loosen the retaining screw (b) fixing the internal-
front cover (a).
Fig. 11 Remove the internal front cover (a) by pressing
the knobs (c).
Fig. 12 Loosen the 3 bolts (d) fixing the internal grille (e)
and separate it from the support plate (f).
Install the HV-fan as follows:
Fig. 13 Pull the internal grille (e) towards you and take the
rubber mountings (g) away from the screws (h).
Fig. 14 Fix the threaded rods (n) to the screws (h) on the
external grille (e) with the threaded couplers (p)
supplied and put back the rubber mountings (g)
on the rods.
Fig. 15 From the outside, place the external grille (e)
over the hole in the wall. From the inside, turn
and push the rubber mountings (g) until they are
located against the wall keeping the external gri-
lle (e) in its correct position.
Fig. 16 Mount the support plate (f) to the threaded rods
(n) and tighten the bolts (d) to suit the length of
the rod sticking out from the support plate (f).
Fig. 17 Fix the support plate (f) to the wall and tighten
bolts (d).
Fig. 18 Depending on the position of the incoming elec-
trical cables, make a hole on the gland (i) on the
front cover (a) or in the gland (p) on the support
plate (f), introduce the electrical cables through
the clamp (j) and connect to the terminal box (k).
Fig. 19 Mount the internal cover (a) by slotting the retan-
gular openings (1) on the top of the cover (a) into
the receivers (m) of the support plate (f) until the
two knobs (c) are correctly positioned.
Fig. 9
Tighten the locking screw (b).
Ensure the shutter arm (v) is located into the shutter
slot when the External grille is fitted. Finally check for
correct running and shutter operation.
ELECTRICAL WIRING
This appliance is considered to be suitable for
use in coun- tries having a warm damp equa-
ble climate as specified in IEC 60721-2-1. It may
also be used in other countries.
Before proceeding with electrical connections, make sure
it is disconnected from the network.
Also, make sure that the impeller turns freely and there
are no obstructions in the fan inlet or outlet.
Means for disconnection must be incorperated in the
fixed wiring in accordance with the wiring rules. The elec-
trical installation should be made with a multipolar iso-
lating switch with an opening distance between contacts
of at least 3 mm.
The HV-230 and HV-300 models can be connected via
electrical accessories CR-150 (Fig. 3) and REB-1R (Fig.D).
Also it can be connected the device without any accesso-
ries according the Fig,C.
MAINTENANCE
Before handling the fan, make sure it is disconnected
from the mains supply. Clean regularly with a soft cloth
moistened with water. Periodically check the state of the
impeller. Do not clean with pressure water jet.
REMOVAL FROM SERVICE, DISPOSAL AND
RECYCLING
The CEE norm and our commitment to future
generations require us to recycle waste materi-
al; please deposit all remaining elements of the
packaging into containers for recycling, and car-
ry the equipment that has been replaced to the
nearest waste centre or your dealer.
TECHNICAL ASSISTANCE
The extensive S&P Official Services Network guarantees
competent technical assistance anywhere in Spain.
If any anomalies are observed in the appliance, please
contact any of the Technical Services on the list to deal
with your problem.
Any handling of the appliance by persons other than S&P
Official Services will lead to the guarantee being can-
celled.
S&P reserves the right to make any modifications with-
out prior notice.
EN