Descargar Imprimir esta página

i.safe MOBILE MVS1A01 Manual De Instrucciones página 16

Publicidad

The following messages may appear on the display after the System Check:
Message
(Senseven App)
"X Hardware connection" Side connection faulty
"X Coupling"
Green message: No Valve Sense Inspection Set error.
REPAIR
WARNING
Incorrect repairs present a risk of explosion or fire, which can result in death or severe injuries!
Do not open the device or carry out any repairs yourself.
Contact the i.safe MOBILE GmbH repair service at
www.isafe-mobile.com/en/support/service if the device is not working normally, if the
device needs to be repaired or if a replacement part is required.
RETURN SHIPMENT
Contact the i.safe MOBILE GmbH repair service at
www.isafe-mobile.com/en/support/service
16
Cause
Measurement electronics faulty
One of the two cables is faulty
Both cables faulty
One of the sensors is faulty
Both sensors faulty
No coupling foil present
Further action
Send the complete Valve Sense
Inspection Set to the i.safe
MOBILE GmbH repair service.
Orange message:
Stick on the coupling foil and
carry out a System Check.
If the error message appears
again, send the complete Valve
Sense Inspection Set to the
i.safe MOBILE GmbH repair
service.
Red message:
Send the complete Valve
Sense Inspection Set to the
i.safe MOBILE GmbH repair
service in any case.

Publicidad

loading

Este manual también es adecuado para:

Is-vs1a.1