1. LED light warning signals
This product features functions that are designed to
protect the tool itself as well as the battery.
If any of the safeguard functions activate during
operation, the LED light will blink as described in
Table 5.
When any of the safeguard functions are triggered,
immediately remove your finger from the switch and
follow the instructions described under corrective
action.
LED light
LED Light
Status
Display
On 0.5 second/
Battery low
off 0.5 second)
High
Temperature
State
On 0.25 second/
off 0.25 second)
Low
Temperature
State
Table 5
Corrective Action
The battery
remaining power is
empty
Recharge the battery
as soon as possible
Machine is in too hot
condition
Allow the stapler to
cool thoroughly in
adequate condition
Machine is in too
cold (below 23°F
(-5°C)) condition
Allow the stapler to
warm-up thoroughly
in adequate
condition
LED Light
Status
Display
Blinking other
than as
Other errors
described
above
CAUTION
● Do not expose directly your eye to the light by
looking into the light.
If your eye is continuously exposed to the light,
your eye will be hurt.
● Wipe off any dirt or grime attached to the lens of
the LED light with a soft cloth, being careful not
to scratch the lens.
Scratches on the lens of the LED light can result
in decreased brightness.
2. Remaining battery indicator
You can check the battery's remaining capacity by
pressing the remaining battery indicator switch to light
the indicator lamp. (Table 6)
It is best to use the remaining battery indicator as a
guide since there are slight differences such as
ambient temperature and the condition of the battery.
Also, the remaining battery indicator may vary from
those equipped to a tool or charger.
Remaining battery
indicator lamp
Display panel
English
Corrective Action
Remove the battery
and clean the area
around the blade
guide and driver
blade according to
the instructions on
page 23.
If performing the
above does not
correct the problem,
contact a
metabo HPT
authorized service
center.