How to proceed:
1. Turn the casing cover counterclockwise as far as the stop.
– Rotational direction symbol "Open lock".
– The casing cover can be very firmly seated. If necessary, insert a rod through the lugs to
achieve greater leverage.
2. Carefully pull the quartz glass and cleaning rotor out of the casing.
3. Clean the quartz glass and the cleaning rotor.
– Pull off the cleaning rotor and clean with a brush under running water.
– Wipe the quartz glass with a damp cloth.
– Thoroughly clean the inner and outer surfaces of the casing.
4. Replace the quartz glass if it is damaged or very scratched.
– Undo the clamping screw and pull the quartz glass, together with the O ring, from the cas-
ing cover.
– Clean the O ring and lubricate with OASE grease (order No. 27872). Replace the O ring if it is
damaged.
5. Fit the quartz glass together with the O ring onto the casing cover and screw in the clamping
screw as far as the stop.
– Pull the O ring over the flanged rim to avoid grease residue coming into contact with the
quartz glass.
– Ensure that the clamping screw audibly engages, otherwise the casing cover cannot be fit-
ted into the casing.
6. Check the profile wear at both ends and the inner surfaces on the cleaning rotor.
– If the profile is worn, the cleaning rotor rotates sluggishly and has to be replaced.
7. Push the cleaning rotor onto the quartz glass.
– Ensure that it is correctly positioned.
8. Carefully push the quartz glass and the cleaning rotor into the casing.
9. Turn the casing cover clockwise as far as the stop.
– Rotational direction symbol "Close lock".