Descargar Imprimir esta página

Oase Bitron Eco 120 W Instrucciones De Uso página 50

Ocultar thumbs Ver también para Bitron Eco 120 W:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 105
Malfunction
Lamp does not light up.
Droplets forming at the con-
nection to the filter.
The unit head cannot be re-
moved.
Display of different tempera-
ture values when several OASE
units with temperature display
are used.
50
Cause
Safety switch-off activated.
Insufficient sealing.
The locking screw has not been
undone.
A vacuum has formed inside the
unit.
Tolerance range of the tempera-
ture measurement
Remedy
For safety reasons, the lamps are deac-
tivated when the unit is opened.
When lamps are defective, ErL1 or ErL2
appears on the display.
 Check the seal position.
 Tighten the screw connection.
Undo the locking screw.
Switch on the unit and allow it to warm
up for a few minutes. Subsequently pull
the power plug and remove the unit
head.
The temperature probes are precise to
 1 °C. If other units with temperature
display are operated, the displayed tem-
perature values may differ from one an-
other by up to 2 °C.
 Recommendation: The arithmetic
mean of all displayed values produces
a useful approximation of the actual
temperature.
 Greater deviations are possible if the
units are exposed to direct sunlight.
For this reason, ensure that the unit
is installed such that it is protected
from direct sunlight.

Publicidad

loading

Este manual también es adecuado para:

Bitron eco 180 wBitron eco 240 w