Water tanks.
Water from hands drops directly to a removable double water tank system. The water
fills in advance the internal upper tank. In low traffic installations, the water will evaporate
and it won't be needed to empty the tank. In medium & high traffic installations, the inner
tank will be filled and this tank, through an overflow feature will fill he visible outer tank.
When water from the lower water tank reaches the 'full level' an acoustic alarm sounds
and the blue pilot light bright (see Fig.). In this case, water in the tank must be emptied.
It is recommended to check, empty and clean the tanks periodically. The periodicity must
be adjusted according to the installation traffic.
• To remove the inner tank, once removed the lower tank according to the figure, pull it
down using the two central ribs. Empty and clean the tank and assembly it back.
Drain pipe connection
The U-flow hand drier is ready to be connected to the drain pipe. Remove the cover
and connect the internal drain pipe tank side to the arrow marked hole at the back part
of the hand dryer. Assembly the cover.