Install a siphoned floor drain with grating below the
water drain cock of Boiling pans and in front of Bratt
pans.
8. CONVERSION TO
ANOTHER TYPE OF GAS
Table Tab1 specifies:
-
which gas can be used for the appliance.
-
the nozzles and settings for each gas that can be
used.
-
For nozzles, the number indicated in table TAB1 is
also stamped on the body of nozzles.
To convert the appliance to the local gas type, follow
the instructions given in TAB1 andcarry out the steps
below:
-
Replace the main burner nozzle (UM).
-
Adjust the main burner's air regulator to distance A.
-
Replace the pilot burner nozzle (UP).
-
Adjust the pilot burner air " ow (if necessary).
-
Replace the gas valve minimum nozzle (Um).
-
Affix the adhesive tab indicating the new type of gas
used.
-
The nozzles and adhesive tabs are supplied with the
appliance.
REPLACING THE NOZZLE AND THE MAIN
BURNER PRIMARY AIR REGULATION
-
Open the door.
-
Remove nozzle UM and replace it with the one
indicated in table TAB1.
-
Retighten nozzle UM.
-
Slacken screw V and position the air regulator at
distance A as indicated in table TAB1.
-
Retighten screw V fully.
-
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE PILOT BURNER NOZZLE
-
Open the door.
-
Undo connector R.
-
Remove nozzle UP and replace it with the one
indicated in table TAB1.
-
Retighten connector R. Reassemble all parts.
-
For assembly, proceed in reverse order.
9. COMMISSIONING
Following installation, conversion to a different type
of gas or any maintenance operations, check
appliance operation. In the event of any malfunction,
consult the next Paragraph "Trouble-shooting".
GAS APPLIANCES
Switch on the appliance as directed in the
instructions and reminders for use given in Chapter "
INSTRUCTIONS FOR USE " and check:
-
the gas supply pressure (see next Paragraph).
-
the correct ignition of the burners and the
effectiveness of the fumes removal system.
CHECKING THE GAS SUPPLY PRESSURE
-
To measure the gas supply pressure use a
manometer with a minimum definition of 0,1 mbar.
-
Remove the control panel.
-
Remove the screw from on pressure test point PP and
connect the manometer to the test point.
-
Make the measurement with the appliance in
operation.
IMPORTANT! IF THE GAS SUPPLY
PRESSURE IS NOT WITHIN THE
LIMITS (MIN. - MAX) INDICATED IN
TABLE TAB2, CEASE OPERATION OF
THE APPLIANCE AND CONTACT THE
GAS UTILITY COMPANY.
-
Disconnect the manometer and retighten the
retaining screw on the pressure connection.
ELECTRICAL APPLIANCES
Switch on the appliance as directed in the
instructions and reminders for use given in Chapter "
INSTRUCTIONS FOR USE " and check:
-
the current values of each phase.
-
the correct operation of the heating elements.
INSTRUCTIONS FOR USE