Electrical
Connection
to the
Range
(U.S.A.)
This appliance is manufactured
with the neutral terminal
connected to the frame.
Silver colored Terminal
Red wire
Note: Refer to the wiring diagram in the center pages of
this manual.
Three
Conductor
Wire
Connection
to
Range
(The 3-conductor
cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 3):
,
Remove the 3 screws at the lower end of the rear
wire cover, then bend the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection
block (see Figure 2).
Terminal
Block
Black
wire
A strainrc
supplied by the user
must be installed at
this location
[o 240 V
receptacle
Figure 3
-1/8" Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Figure 2
BEND REARWIRE COVER HERE
FOR ACCESS TO TERMINAL BLOCK
2. Using the nuts supplied in the literature package,
connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of
the terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
3. Lower the terminal cover and replace the 3 screws.
Four
Conductor
Wire
Connection
to
Range
(mobile
homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection
block (see Figure 2).
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 4).
4. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).