his exhaust system must be properly
maintained.
Do nothing that might
render the
exhaust system unsafe or in noncompliance
with any local codes and/or standards.
_t
The manufacturer
recommends
installing
a battery
operated
carbon monoxide
alarm
indoors, according
to the manufacturer's
instructions.
NEVER use in the home, or in partly enclosed
areas such as garages, campers or trailers.
ONLY
use outdoors and far from open windows, doors,
vents.
Using a generator indoors CAN KiLL YOU iN MINUTES.
Generator exhaust contains carbon monoxide.
This is
a poison you cannot see or smelJ.
NEVER use inside a home
or garage, EVEN iF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
2. Removethefuel cap and checkthe fuel level. If fuel is needed,
see the section "FUELING THEGENERATOR".
3. Remove the left side service cover and check the oil level
by removing the oil filler cap. The oil level should be to the
bottom of the threads on the oil fill pipe. If oil is needed,see
the section "ADDING ENGINE OILL
4. Replaceand securethe left side service cover.
5. Make sure there are no loads connectedto the generator.
6. The National Electric Code (NEC) requires the frame and
external electrically conductive parts of the generator be
properly connected to an approved earth ground. Proper
grounding of the generator will prevent electrical shock in
the event of a ground fault condition in the generator or in
connected electrical devices. Proper grounding also helps
dissipatestatic electricity, which often builds up in unguarded
devices.
7. Local electrical codes may also require proper grounding of
the generator.
CAUTION!
_t
tarting
the generator
with accessories
connected
to the 120 VAC outlets
will
damage the generator
and the connected
devices.
STARTING THE GENERATOR
Once the fuel and oil levels have been checked and it has been
verified there are no loads connected, the generator may be
started. Turnthe FlexPowerSwitch OFF(0).
1. Openthe fuel valve (Figure4), located below the starter rope
pull, byturning to the valve 90° counter-clockwiseto the "ON"
(I) position.
2. Locate the primer bulb (See Figure 5). Slowly, fully depress
the primer bulb and release.Allow the primer bulb to returnto
its original state. Repeatthis six (6) more times.
3. If the engineis cold or hasnot beenrun for some time, engage
the choke by pushingthe choke leverto the right (Figure6).
4. Grip the handlefor the pull starter and brace your other hand
against the generator.Pull the rope slowly until resistance is
felt, then pull the rope rapidly up to three (3) times.
5. If the engine does not start, repeatsteps 2-4 until the engine
fires and beginsto run.
Figure4 - Fuel Va/ve
TURNING
THE F_
-_
6. Carefully adjust the choke to approximatelythe 1/2position
until the engine beginsto run smoothly,then push the lever all
the way to the left (Figure6).
7. Make surethe bottom of the generatoris not blocked by sand,
leaves, grass, etc. as the cooling vents are located on the
bottom of the unit.
Figure 5 - Prime FuelSystem