5.2
Technical data
Mains voltage
Rated current
Frequency
Insulation class
Protection class
Power consumption P
Nominal diameters
Connection flange
Pump weight
Permissible
ambient temperature
Max. rel. humidity
Approved fluids
Permissible
fluid temperature
Max. permissible
Operating pressure
Emission
sound-pressure level
Emitted interference
Interference resistance
CAUTION! Risk of personal injury and material damage!
Non-approved fluids can damage the pump and also cause injury.
Comply strictly with the relevant safety data sheets and manufacturer
specifications!
Installation and operating instructions Wilo-TOP-Z
1~ 230 V in accordance with DIN IEC 60038
3~ 400 V in accordance with DIN IEC 60038
3~ 230 V in accordance with DIN IEC 60038
(optionally with switching plug)
For other voltages see rating plate
See rating plate
See rating plate (50 Hz)
See rating plate
See rating plate
See rating plate
1
See type key
See type key
Depends on the pump type (see catalogue)
-20 °C to +40 °C
≤ 95 %
Drinking water and water for food companies according to
EC Drinking Water Directive.
The choice of material of the pumps corresponds to the
state of the art by taking into account the guidelines of the
German Federal Environmental Agency (UBA), as stated in
the German Drinking Water Ordinance (TrinkwV)
Chemical disinfectants can cause damage to materials.
Drinking water:
up to 20°d: max. +80 °C (for short period (2 h): +110 °C)
Exception: TOP-Z 20/4 and 25/6:
up to 18°d: max. +65 °C (for short period (2 h): +80 °C)
See rating plate
< 50 dB(A)
(depending on the pump type)
EN 61000-6-3
EN 61000-6-2