_
R__"_N
C_
MODEL
B5936SS
Page 3
INSTALL CEILING SUPPORT
PREPARE THE HOOD
CEILING
JOISTS
CROSS
FRAMING
CEILING
MOUNTING
PLATE
(8) M6 x 40mm
WOOD
SCREWS
6" ROUND DUCTWORK
HOUSE
WIRING
ELECTRICAL
OUTLET
BOX
(4) M4 x 8ram
PAN HEAD
SHEET METAL
SCREWS
!
I
DAMPER / DUCT
CONNECTOR
1. Place the hood on flat surface with protection to insure the
hood is not damaged.
2. Attach the damper / duct connector to the hood with (4) M4
x 8mm pan head sheet metal screws.
1. At hood location install 2 x 4 cross framing between ceiling
joists using dimensions shown. Make sure framing does not
interfere with electrical outlet box opening in ceiling mount-
ing plate.
2. Install house wiring and ductwork.
3. Finish ceiling surface. Be sure to mark the location of the
ceiling joists & cross framing. Bring house wiring through
finished ceiling.
4. Remove cover from electrical outlet box on ceiling mount-
ing plate. Pull house wiring through hole on top of mounting
plate and into electrical outlet box. Secure house wiring
cable to mounting plate / electrical box with appropriate
connector.
5. Install ceiling mounting plate with the side marked ffront"
at the desired hood location. Secure using (8) M6 x 40mm
wood screws. Make sure screws are driven into the center
of the framing for maximum strength.