(8) M4 x 10ram
PAN HEAD
MACHINE
SCREWS
1. Assemble (4) angle brackets to the hood using (8) M4
x 10mm pan head machine screws (2 for each angle
bracket).
(16) M4 x 10mm
PAN HEAD
MACHINE
SCREWS &
(16) M4
SERRATED
FLANGE NUTS
3.
4.
Attach the upper set of (4) angle brackets to the outside of
the lower angle brackets according to dimension "H". Use
(16) M4 x 10mm pan head machine screws and (16) M4
serrated flange nuts (4 at each angle bracket connection).
Attach the angle bracket assemblies to the upper hood
mounting locations using (8) M4 x 10mm pan head machine
screws (2 for each angle bracket).
For 10-ft. ceilings: Attach a third set of (4) angle brackets
to the inside of the second set of angle brackets using
hardware supplied.
(4) M4 x 8mm
SHEET METAL
SCREWS
NON-DUCT
PLENUM
FLEXIBLE
DUCT
DAMPER /
DUCT
CONNECTOR
INNER
FLUE
POWER
CABLE
DUCT
TAPE
2. Determine dimension "H" based upon ceiling height and
height of hood installation above cooktop:
8-ft. ceiling
Hood 30" above cooktop
H = 30"
Hood 301/2 '' above cooktop H = 291/2 ''
9-ft. ceiling
Hood 30" above cooktop
H = 42"
Hood 36" above cooktop
H = 36"
10-ft. ceiling
Hood 30" above cooktop
H = 54"
Hood 36" above cooktop
H = 48"
For 10-ft. ceilings:
Purchase a 10-ft. flue extension (Model
FXN59SS) which includes (4) additional angle mounting
brackets, (1) longer upper flue, and additional mounting
hardware.
6.
6.
7.
8.
Measure the length of 6" round flexible duct required from
the damper / duct connector to the ductwork rough-in in the
ceiling. Connect the duct to the damper / duct connector,
secure with tie wrap and seal with duct tape.
Attach the aluminum flexible duct to the non-duct plenum
collar. Make sure non-duct plenum "front" is facing front of
hood. Secure with tie wrap and seal with duct tape.
Remove the protective coating from the inner the flue. Turn
the inner flue so that the louvers are at the top. Carefully
slide the inner flue down into the outer flue. Slide the flues
over the angle brackets. Make sure the side marked "front"
faces the control side of the hood. Feed the power cable up
through the flues.
Pull the inner flue up and attach the non-duct plenum with
collar to the upper flue using (4) M4 x 8ram sheet metal screws.