Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

TLX-3 illustré avec robinet et distributeur de savon Verge™
Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation.
Electrical power MUST remain off until installation is complete.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 lb.
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Read this entire installation manual to ensure proper installation. When finished with the installation, file
this manual with the owner or maintenance department. Compliance and conformity to local codes and
ordinances is the responsibility of the installer. Product warranties may be found under "Products" on our
website at bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the
finished floor.
215-1902 Rev. C: ECO 20-08-028B
© 2021 Bradley
Page 1 of 73
1/21/2021
GLX-3 shown with WashBar Duo WBD1
GLX-3 illustré avec WashBar Duo WBD1
Se muestra GLX-3 con WashBar Duo WBD1
TLX-3 shown with Verge™ Soap & Faucet
Se muestra TLX-3 con llave y jabón Verge™
WARNING
NOTICE
IMPORTANT
Installation
GLX-3 and TLX-3
Express Lavatory System –
GLX & TLX Series
Système lave-mains Express –
Série GLX et TLX
Sistema de lavabo Express –
Series GLX y TLX
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
P.O. Box 309
bradleycorp.com

Publicidad

loading

Resumen de contenidos para Bradley GLX-3

  • Página 1 Système lave-mains Express – GLX-3 shown with WashBar Duo WBD1 GLX-3 illustré avec WashBar Duo WBD1 Série GLX et TLX Se muestra GLX-3 con WashBar Duo WBD1 Sistema de lavabo Express – Series GLX y TLX TLX-3 shown with Verge™ Soap & Faucet TLX-3 illustré...
  • Página 2 Conjunto de componentes de llave y jabón Verge o WashBar Duo ....................70 Montaje de la palangana ................................71 Filtro y sifón en P ..................................71 Ajuste de temperatura ................................... 72 Panel de acceso .................................... 72 Limpieza y mantenimiento ................................73 Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 3 S53-3500, & S53-3700 (½" NPTM Outlet) (S45-2701) Plastic Plastic Hose Hose Plastic Hose Plastic Supply Fittings Plastic Hose (S45-3005) Hose for Verge Faucets Stainless Steel S53-3100, S53-3300, Hose Prepack Hose S53-3500, & S53-3700 (S45-2730) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 4 • OPTIONAL: (3) 110V GFCI protected electrical outlets for 100–120 VAC plug-in transformers • Screen filter(s) as needed, if not included with faucet(s) Dimensions (mm) Top View – GLX-3 (shown with Verge™ Soap & Faucet) 85³⁄₈" (2168) 42⁵⁄₈" (1084) 13⁷⁄₈" (354) 2⁹⁄₁₆"...
  • Página 5 Installation GLX-3 / TLX-3 Dimensions (mm) Top View – GLX-3 (shown with WBD1) 85³/₈" (2168) 42⁵⁄₈" (1084) 4" (102) 13⁷/₈" (354) 5¹⁄₈" (130) 20⁵⁄₈" (525) Front View – GLX-3 (shown with WBD1) 7¹⁄₈" (181) 19¹⁄₈" (486) 34" (864) 77⁵⁄₈" (1971) Finished Floor Bradley •...
  • Página 6 42⁵⁄₈" (1083) 15" (381) 2⁹⁄₁₆" (65) 6" (152) 6" (152) 5¹⁄₈" (130) 20⁵⁄₈" (525) Front View – TLX-3 (shown with Verge Soap & Faucet) 19¹⁄₈" (486) 34" (864) 77⁵⁄₈" (1971) Finished Floor Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 7 85¼" (2166) 42⁵⁄₈" (1083) 15" (381) 4" (102) 5¹⁄₈" (130) 20⁵⁄₈" (525) 27⁵⁄₈" (702) 27⁵⁄₈" (702) Front View – TLX-3 (shown with WBD1) 7¹⁄₈" (181) 19¹⁄₈" (486) 34" (864) 77⁵⁄₈" (1971) Finished Floor Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 8 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 9 OBC Height – Verge Faucet OBC Height – WBD1 20⁵⁄₈" (524) 20⁵⁄₈" (524) 17⁵/₈" (448) 12⁷⁄₈" 10⁷⁄₈" (326) (278) 8⁵⁄₈" 6⁷⁄₈" (173) (219) 33¹⁄₈" 33¹⁄₈" 28⁷⁄₈" 28⁷⁄₈" (840) (840) (735) (735) 13⁷⁄₈" 13⁷⁄₈" (352) (352) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 10 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 11 OBC Height – WBD1 20⁵⁄₈" (524) 20⁵⁄₈" (524) 17⁵/₈" (448) 17½" (445) 12¾" 10⁷⁄₈" (325) (278) 8⁵⁄₈" 6¾" (172) (219) 33¹⁄₈" 33¹⁄₈" 28⁷⁄₈" 28⁷⁄₈" (840) (840) (735) (735) 13⁷⁄₈" 13⁷⁄₈" (352) (352) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 12 At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance. 26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 13 QTY. 1½" NPT Drain, Stub-out 2" from wall, individual waste option ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 110V GFI protected electrical outlet (AC faucet and soap only) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 14 QTY. 1½" NPT Drain, Stub-out 2" from wall, individual waste option ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 110V GFI protected electrical outlet (AC faucet and soap only) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 15 1½" NPT Drain, Stub-out 2" from wall, combined waste option ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 110V GFI protected electrical outlet (AC faucet and soap only) 3¼" (84) 24¼" (616) 20⁵⁄₈" (525) 8¹⁄₈" (205) Finished Floor Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 16 1½" NPT Drain, Stub-out 2" from wall, combined waste option ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 110V GFI protected electrical outlet (AC faucet and soap only) 3¼" (84) ½" (13) 15¼" (394) 14¼" (368) Finished Floor Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 17 5½" 7" (178) (139) 8" Faucet Box (3x) (203) 23" (584) 16" (406) Finished Floor CODE DESCRIPTION QTY. #10 Anchors for Faucet Control Box Installation Provide sufficient backing behind the mounting locations. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 18 8¼" (210) (3x) 5½" (140) 30¾" (781) 20¾" (527) Finished Floor CODE DESCRIPTION QTY. #10 Anchors for Soap Tank Bracket (100 lb pull out force) Provide sufficient backing behind the mounting locations. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 19 6³/₈" (161) 34" (864) 19" (483) 18¼" (464) 24" (610) Soap Battery Box (3x) Finished Floor CODE DESCRIPTION QTY. #10 Anchors for Soap Tank Installation Provide sufficient backing behind the mounting locations. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 20 6³/₈" (161) 30¼" (769) Multi-Feed 18¼" (464) 24" (610) Soap Battery Tank Box (4x) Finished Floor CODE DESCRIPTION QTY. #10 Anchors for Soap Tank Installation Provide sufficient backing behind the mounting locations. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 21 Step B and marked at 28" both to the left and right of the center bracket. Secure the brackets to the wall anchors using fasteners per the structural rough-in requirement (supplied by installer) (3x). Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 22 IMPORTANT: While the bowl is free from the wall, assemble the components for the Verge soap & faucet or WashBar Duo assemblies. Refer to the Verge soap & faucet and WashBar Duo installation instructions. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 23 Ensure bowl is level. Strainer and P-Trap Ensure not to overtighten the strainer screw. Strainer Thread the strainer screw through the strainer and into the stand off on the drain adapter. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 24 Shown with WashBar Duo. Verge Soap and Faucet similar. Hang the access panel onto the access panel brackets as shown, and then secure the access panel with the thumb screws provided, starting with either the left or right side. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 25 Avoid contact with hot pans and objects. Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days.
  • Página 26 Pour les poses de hauteur standard, ne pas dépasser la distance conseillée de 851 mm (33,5 po) entre le rebord du lavabo et le sol fini. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 27 Tuyau en Tuyau en plastique plastique Tuyau en plastique Tuyau en Raccords d’alimentation Tuyau en plastique (S45-3005) plastique pour robinets Verge Tuyau en acier S53-3100, S53-3300, Trousse tuyaux inoxydable S53-3500 et S53-3700 (S45-2730) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 28 100–120 V c.a. • Filtre(s) à tamis selon les besoins, si non fourni(s) avec le(s) robinet(s) Dimensions mm (po) Vue de dessus – GLX-3 (illustré avec robinet et distributeur de savon Verge™) 2168 (85³⁄₈) 1084 (42⁵⁄₈) 354 (13⁷⁄₈) 65 (2⁹⁄₁₆)
  • Página 29 Installation GLX-3 / TLX-3 Dimensions mm (po) Vue de dessus – GLX-3 (illustré avec WBD1) 2168 (85³/₈) 1084 (42⁵⁄₈) 102 (4) 354 (13⁷/₈) 130 (5¹⁄₈) (20⁵⁄₈) Vue de face – GLX-3 (illustré avec WBD1) 181 (7¹⁄₈) (19¹⁄₈) (34) 1971 (77⁵⁄₈) Plancher fini Bradley •...
  • Página 30 1083 (42⁵⁄₈) 381 (15) 65 (2⁹⁄₁₆) 152 (6) 152 (6) 130 (5¹⁄₈) (20⁵⁄₈) Vue de face – TLX-3 (illustré avec robinet et distributeur de savon Verge) (19¹⁄₈) (34) 1971 (77⁵⁄₈) Plancher fini Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 31 Vue de dessus – TLX-3 (illustré avec WBD1) 2166 (85¼) 1083 (42⁵⁄₈) 381 (15) 102 (4) 130 (5¹⁄₈) (20⁵⁄₈) 702 (27⁵⁄₈) 702 (27⁵⁄₈) Vue de face – TLX-3 (illustré avec WBD1) 181 (7¹⁄₈) (19¹⁄₈) (34) 1971 (77⁵⁄₈) Plancher fini Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 32 660 mm (26 po) *Retrancher 203 mm Junior Installations pour jeunes enfants non soumises aux normes ADA. (8 po) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 33 (7¾) (7¾) (14⁵⁄₈) (14⁵⁄₈) Hauteur OBC – robinet Verge Hauteur OBC – WBD1 524 (20⁵⁄₈) 524 (20⁵⁄₈) 448 (17⁵/₈) (12⁷⁄₈) (10⁷⁄₈) 219 (8⁵⁄₈) 173 (6⁷⁄₈) (33¹⁄₈) (33¹⁄₈) 735 (28⁷⁄₈) (28⁷⁄₈) (13⁷⁄₈) (13⁷⁄₈) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 34 660 mm (26 po) *Retrancher 203 mm Junior Installations pour jeunes enfants non soumises aux normes ADA. (8 po) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 35 (7¾) (7¾) (14⁵⁄₈) (14⁵⁄₈) Hauteur OBC – robinet Verge Hauteur OBC – WBD1 524 (20⁵⁄₈) 524 (20⁵⁄₈) 448 (17⁵/₈) 445 (17½) (12¾) (10⁷⁄₈) 172 (6¾) (8⁵⁄₈) (33¹⁄₈) (33¹⁄₈) (28⁷⁄₈) (28⁷⁄₈) (13⁷⁄₈) (13⁷⁄₈) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 36 660 mm (26 po) *Retrancher 203 mm Junior Installations pour jeunes enfants non soumises aux (8 po) normes ADA. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 37 Arrivées d’eau chaude/froide ½ po nominal (comp. dia. ext. ⁵⁄₈ po), tubulure à 51 mm (2 po) du mur Prise électrique de 110 V à disjoncteur différentiel (GFCI) (robinet et distributeur de savon à c.a. uniquement) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 38 Arrivées d’eau chaude/froide ½ po nominal (comp. dia. ext. ⁵⁄₈ po), tubulure à 51 mm (2 po) du mur Prise électrique de 110 V à disjoncteur différentiel (GFCI) (robinet et distributeur de savon à c.a. uniquement) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 39 Arrivées d’eau chaude/froide ½ po nominal (comp. dia. ext. ⁵⁄₈ po), tubulure à 51 mm (2 po) du mur Prise électrique de 110 V à disjoncteur différentiel (GFCI) (robinet et distributeur de savon à c.a. uniquement) 84 (3¼) 616 (24¼) 525 (20⁵⁄₈) 205 (8¹⁄₈) Plancher fini Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 40 Arrivées d’eau chaude/froide ½ po nominal (comp. dia. ext. ⁵⁄₈ po), tubulure à 51 mm (2 po) du mur Prise électrique de 110 V à disjoncteur différentiel (GFCI) (robinet et distributeur de savon à c.a. uniquement) 84 (3¼) 13 (½) 394 (15¼) 368 (14¼) Plancher fini Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 41 (3x) 584 (23) 406 (16) Plancher fini CODE DESCRIPTION QTÉ Chevilles d’ancrage n° 10 pour la pose du boîtier de commande de robinet Prévoir un renfort suffisant derrière les emplacements de fixation. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 42 527 (20¾) Plancher fini CODE DESCRIPTION QTÉ Chevilles d’ancrage n° 10 pour le support du réservoir de savon (résistance à l’arrachement 0,44 kN/100 lb) Prévoir un renfort suffisant derrière les emplacements de fixation. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 43 Boîtier de batterie de pompe à savon (3x) Plancher fini CODE DESCRIPTION QTÉ Chevilles d’ancrage n° 10 pour la pose du réservoir de savon Prévoir un renfort suffisant derrière les emplacements de fixation. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 44 Boîtier de batterie de d’alimentation pompe à savon (4x) commune Plancher fini CODE DESCRIPTION QTÉ Chevilles d’ancrage n° 10 pour la pose du réservoir de savon Prévoir un renfort suffisant derrière les emplacements de fixation. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 45 à 711 mm (28 po) à gauche et à droite du centre. Attacher les supports aux chevilles d’ancrage murales à l’aide de vis conformes aux indications de la section Poses préliminaires - structure (visserie non fournie) (3x). Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 46 IMPORTANT : Avant d’attacher la vasque au mur, assembler les composants du système Verge eau et savon ou WashBar Duo. Voir les instructions d’installation du système Verge eau et savon ou WashBar Duo. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 47 Tamis et siphon en P Veiller à ne pas trop serrer la vis du tamis. Tamis Engager la vis du tamis à travers le tamis et dans l’entretoise sur l’adaptateur d’écoulement. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 48 Accrocher le panneau d’accès aux supports de panneau d’accès comme sur l’illustration, puis l’attacher à l’aide des vis à oreille prévues à cet effet, en commençant par le côté gauche ou droit. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 49 Éviter le contact avec des casseroles et autres objets chauds. Trousses de réparation : Des nécessaires de réparation Terreon sont disponibles. S’adresser au représentant ou distributeur Bradley pour connaître les numéros de référence et les prix. Les trousses de réparation sont préparées sur commande et ont une durée de conservation de 30 jours.
  • Página 50 Saque las piezas del embalaje y asegúrese de haberlas sacado todas antes de desecharlo. Si falta alguna pieza, no comience la instalación hasta conseguirla. Para montaje en altura estándar, no exceda la distancia recomendada de 851 mm (33,5") desde el borde del accesorio hasta el piso terminado. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 51 Manguera de plástico Manguera Conexiones de Manguera suministro (S45-3005) de plástico plástico para llaves Verge Manguera de Conjunto S53-3100, S53-3300, acero inoxidable preempaquetado de S53-3500 y S53-3700 manguera (S45-2730) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 52 110 V, para transformadores conectables de 100 a 120 V CA • Filtros de malla según sean necesarios, si no se incluyen con las llaves Dimensiones mm (pulg.) Vista superior – GLX-3 (se muestra con llave y jabón Verge™) 2168 (85³⁄₈") 1084 (42⁵⁄₈") 354 (13⁷⁄₈") 65 (2⁹⁄₁₆")
  • Página 53 Installation GLX-3 / TLX-3 Dimensiones mm (pulg.) Vista superior – GLX-3 (se muestra con WBD1) 2168 (85³/₈") 1084 (42⁵⁄₈") 102 (4") 354 (13⁷/₈") 130 (5¹⁄₈") (20⁵⁄₈") Vista delantera – GLX-3 (se muestra con WBD1) 181 (7¹⁄₈") (19¹⁄₈") (34") 1971 (77⁵⁄₈") Piso terminado Bradley •...
  • Página 54 2166 (85¼") 1083 (42⁵⁄₈") 381 (15") 65 (2⁹⁄₁₆") 152 (6") 152 (6") 130 (5¹⁄₈") (20⁵⁄₈") Vista delantera – TLX-3 (se muestra con llave y jabón Verge) (19¹⁄₈") (34") 1971 (77⁵⁄₈") Piso terminado Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 55 Vista superior – TLX-3 (se muestra con WBD1) 2166 (85¼") 1083 (42⁵⁄₈") 381 (15") 102 (4") 130 (5¹⁄₈") (20⁵⁄₈") 702 (27⁵⁄₈") 702 (27⁵⁄₈") Vista delantera – TLX-3 (se muestra con WBD1) 181 (7¹⁄₈") (19¹⁄₈") (34") 1971 (77⁵⁄₈") Piso terminado Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 56 660 mm (26") *Reste 203 mm (8") Para niños Para uso por niños pequeños donde las pautas de ADA no sean una preocupación. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 57 (29⁷₈") (7¾") (7¾") (14⁵⁄₈") (14⁵⁄₈") Altura OBC – Llave Verge Altura OBC – WBD1 524 (20⁵⁄₈") 524 (20⁵⁄₈") 448 (17⁵/₈") (12⁷⁄₈") (10⁷⁄₈") 219 (8⁵⁄₈") 173 (6⁷⁄₈") (33¹⁄₈") (33¹⁄₈") (28⁷⁄₈") (28⁷⁄₈") (13⁷⁄₈") (13⁷⁄₈") Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 58 660 mm (26") *Reste 203 mm (8") Para niños Para uso por niños pequeños donde las pautas de ADA no sean una preocupación. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 59 (7¾") (14⁵⁄₈") (14⁵⁄₈") Altura OBC – Llave Verge Altura OBC – WBD1 524 (20⁵⁄₈") 524 (20⁵⁄₈") 448 (17⁵/₈") 445 (17½") (12¾") (10⁷⁄₈") 219 (8⁵⁄₈") 172 (6¾") (33¹⁄₈") (33¹⁄₈") (28⁷⁄₈") (28⁷⁄₈") (13⁷⁄₈") (13⁷⁄₈") Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 60 660 mm (26") *Reste 203 mm (8") Para niños Para uso por niños pequeños donde las pautas de ADA no sean una preocupación. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 61 Suministros de agua fría y caliente de ½" nominal (diám. ext. comp. de ⁵⁄₈" comp.), suministros de agua H y C fría y caliente, salen 51 mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 62 Suministros de agua fría y caliente de ½" nominal (diám. ext. comp. de ⁵⁄₈" comp.), suministros de agua H y C fría y caliente, salen 51 mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 63 51 mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) 84 (3¼") 616 (24¼") 525 (20⁵⁄₈") 205 (8¹⁄₈") Piso terminado Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 64 51 mm (2") de la pared Tomacorriente protegido por interruptor GFI de 110 V (solo llave y jabón CA) 84 (3¼") 13 (½") 394 (15¼") 368 (14¼") Piso terminado Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 65 (3x) 584 (23") 406 (16") Piso terminado CÓDIGO DESCRIPCIÓN CANTIDAD Anclajes n.º 10 para instalación de la caja de control de la llave Proporcione suficiente soporte detrás de las ubicaciones de montaje. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 66 527 (20¾") Piso terminado CÓDIGO DESCRIPCIÓN CANTIDAD Anclajes n.º 10 para soporte del depósito de jabón (fuerza de extracción de 45 kg/100 lb) Proporcione suficiente soporte detrás de las ubicaciones de montaje. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 67 Caja de las pilas del dispensador de jabón (3x) Piso terminado CÓDIGO DESCRIPCIÓN CANTIDAD Anclajes n.º 10 para la instalación del depósito de jabón Proporcione suficiente soporte detrás de las ubicaciones de montaje. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 68 Caja de las pilas alimentación del dispensador múltiple de jabón (4x) Piso terminado CÓDIGO DESCRIPCIÓN CANTIDAD Anclajes n.º 10 para la instalación del depósito de jabón Proporcione suficiente soporte detrás de las ubicaciones de montaje. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 69 Paso B y marcadas a 711 mm (28") a la izquierda y derecha del soporte central. Fije los soportes a los anclajes de pared con los sujetadores según los requisitos de las tuberías empotradas estructurales (suministradas por el instalador) (3x). Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 70 IMPORTANTE: Mientras la palangana no esté sujeta a la pared, monte los componentes de los conjuntos de jabón y llave Verge o WashBar Duo. Consulte las instrucciones de instalación de jabón y llave Verge y de WashBar Duo. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 71 Filtro y sifón en P Asegúrese de no apretar en exceso el tornillo del filtro. Filtro Enrosque el tornillo del filtro a través del filtro y en el separador del adaptador de desagüe. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 72 Cuelgue el panel de acceso en los soportes del panel de acceso como se muestra, luego fije el panel de acceso con los tornillos de aletas que se proporcionan, comenzando por el lado derecho o izquierdo. Bradley • 215-1902 Rev. C: ECO 20-08-028B 1/21/2021...
  • Página 73 Como refrescar la superficie: Use el limpiador Perfect Countertop de Hope’s ® para refrescar el material de superficie sólida Terreon. Bradley recomienda cuidado y mantenimiento adicional para Terreon de color más oscuro. Para obtener instrucciones completas de este mantenimiento adicional, visite bradleycorp.com. ¡AVISO! No use productos químicos o limpiadores ácidos o alcalinos fuertes para limpiar el Terreon.

Este manual también es adecuado para:

Tlx serieGlx serieTlx-3