Descargar Imprimir esta página

Bradley GLX-3 Instalación página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

GLX-3 / TLX-3
Supplies Required
• (6) ³⁄₈" fasteners and wall anchors (minimum pull-out rating of 1,000 lb)
• (6) ¼" fasteners (2 for the bowl, 4 for the bracket)
• ½" hot/cold or tempered stub-out(s)
• 1½" NPT drain stub-out(s)
• OPTIONAL: (3) 110V GFCI protected electrical outlets for 100–120 VAC plug-in transformers
• Screen filter(s) as needed, if not included with faucet(s)
Dimensions
Top View – GLX-3 (shown with Verge™ Soap & Faucet)
2⁹⁄₁₆" (65)
5¹⁄₈" (130)
20⁵⁄₈"
(525)
Front View – GLX-3 (shown with Verge Soap & Faucet)
34"
(864)
4
42⁵⁄₈" (1084)
13⁷⁄₈" (354)
6" (152)
6" (152)
28¾" (730)
Finished Floor
1/21/2021
85³⁄₈" (2168)
28¾" (730)
77⁵⁄₈" (1971)
Bradley • 215-1902 Rev. C: ECO 20-08-028B
Installation
(mm)
19¹⁄₈"
(486)

Publicidad

loading

Este manual también es adecuado para:

Tlx serieGlx serieTlx-3