Bradley GLX-3 Instalación página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

GLX-3 / TLX-3
Structural Rough-Ins
Mounting for Standard ADA and TAS height shown.
Areas highlighted in gray require sufficient backing
compliant with local building codes.
A
34"
(864)
31¼"
(794)
30½"
(775)
CODE
A
Install (1) ³⁄₈" wall anchor with a minimum pull-out force of 1,000 lb per local codes at locations shown
B
Install (2) wall anchors per bracket with a minimum pull-out force of 100 lb per local codes at locations shown
C
RIM
HEIGHT
34"
31"
26"
12
5³/₁₆" (131)
B
¾" (19)
Access Panel
Mounting Bracket
Provide structural backing compliant with local building codes.
VERTICAL HEIGHT
ADJUSTMENTS
No Adjustment
*Subtract 3"
*Subtract 8"
1/21/2021
36½" (927)
5⁵/₁₆" (135)
C L
B
DESCRIPTION
FIXTURE
STYLE
Standard ADA & TAS
At least one basin must meet dimensional
requirements and have proper reach, knee,
and toe clearance.
Juvenile ADA & TAS
At least one basin must meet dimensional
requirements and have proper reach, knee,
and toe clearance.
Junior
For use by younger children where ADA
guidelines are not a concern.
Secure bracket to wall using min. (2) ³⁄₈"
anchor bolts to the left of C/L and min. (2)
³⁄₈" anchor bolts to the right of C/L. The (2)
anchor bolts to the right of C/L must be
min. 16" apart from the anchor bolts to the
left of C/L. When mounting is complete,
check to ensure the bracket is level.
B
28" (711)
37½" (954)
Finished Floor
C
NOTES
Bradley • 215-1902 Rev. C: ECO 20-08-028B
Installation
(mm)
A
31½"
(801)
16"
(407)
QTY.
2
6
2