Before you store the air compressor,
make sure you do the following:
1,
Review the "Maintenance"
section on the preceding
pages and perform scheduled
maintenance as necessary,
2,
Set the On/Auto/Off
lever to
"Off" and unpiug unit,
3,
Turn the regulator
counterclockwise
and set the
outlet pressure to zero,
4,
Remove the air tool or
accessory.
5,
PulI ring on safety valve alIowing
air to bleed from the tank untiI
tank pressure is approximately
20 psi, Release safety valve ring,
6,
Drain water from air tank by
opening drain valve on bottom of
tank,
Risk of Bursting,
Water will
condense
in the air tank,
If not
drained, water will corrode
and
weaken the air tank causing
a risk
of air tank rupture,
7,
After the water has been
drained, close the drain or drain
valve,
NOTE: If drain valve is plugged,
release all air pressure,
The valve
can then be removed, cleaned, and
reinstalled,
8,
Protect the electrical cord and
air hose from damage (such as
being stepped on or run over),
Wind them loosely around
the compressor
handle, (If so
equipped),
9,
Store the air compressor
in a
clean and dry location,
A09707
20-ENG