OPERATION
EN
9. To transport machine from one room to another,
raise the scrub head to the transport position and
push the machine forward (Figure 16).
DO NOT tilt machine on the rear wheels. Only use
rear wheels to transport machine up and down a
curb.
FIG. 16
Curb
FOR SAFETY: When transporting machine within
the facility, do not wheel up or down stairs. Get
assistance when lifting machine.
BATTERY DISCHARGE INDICATOR
The battery discharge indicator displays the charge
level of the battery (Figure 17).
When the discharge level reaches the red zone, the
machine will automatically shut down (Figure 17).
Recharge battery at this time.
To prolong battery life, do not leave battery discharged
for a lengthy period. When fully charged, the machine
will operate for approximately one hour.
FIG. 17
10
For cleaning machines, parts & supplies click/visit www.southeasternequipment.net
CIRCUIT BREAKERS
The machine is equipped with two resettable circuit
breakers to protect the brush and vacuum motors from
damage (Figure 18). If the brush or vacuum become
obstructed, the circuit breaker will trip. To reset circuit
breaker, turn off the main power switch, remove the
obstruction then reset the circuit breaker button
(Figure 18). If the circuit breaker does not reset
immediately, allow the machine to cool.
FOR SAFETY: Before removing obstruction turn
the main power switch to the off position.
FIG. 18
HOUR METER
The hour meter records the number of total hours the
machine has been powered on. Use the hour meter to
record machine use and service history (Figure 19).
FIG. 19
Tennant T1 Li (09- -10)