5.2.3 Screwdriving
CAUTION
Risk of injury by damaged workpieces! Screws or workpiece can be
damaged if torque is too high. This presents a risk of injury.
▶ Make sure that screws and workpiece are suitable for the torque
produced by the product.
Conditions: Operation without the intelligent torque module
1. Move the forward/reverse switch into the middle position.
2. Use the torque selector button to set the desired torque. → page 11
3. Set the forward/reverse switch to the desired direction of rotation.
When using the intelligent torque module, the torque selector button
does not work. The torque is controlled depending on the type of
screw, threaded stud or anchor selected in the intelligent torque
module (→ Operating instructions for the intelligent torque module).
5.2.4 Switching off
▶ Release the control switch.
6
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance
tasks!
Care of the product
•
Carefully remove stubborn dirt.
•
Carefully clean the air vents, if present, with a dry, soft brush.
•
Use only a slightly damp cloth to clean the housing. Do not use cleaning
agents containing silicone as these can attack the plastic parts.
•
Use a dry, clean cloth to clean the contacts of the product.
Care of the Liion batteries
•
Never use a battery with clogged air vents. Clean the air vents carefully
using a dry, soft brush.
•
Avoid unnecessary exposure of the battery to dust and dirt. Never
expose the battery to high levels of moisture (e.g. by being dipped in
water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery.
Isolate it in a non-flammable container and consult Hilti Service.
12
English
2124662