GB
INSTRUCTIONS FOR USE AND MAINTENANCE
IMPORTANT NOTICE
Read these instructions carefully before using the TURBO
SET and retain them for future reference. They provide all
the necessary information for proper use, avoiding hazards
and equipment damage.
OXYTURBO no liability for injuries caused by improper use
of or changes made to the equipment.
PARTS LIST
O
cylinder 1 lt 110bar
1.
2
M12x1 R. Code 480300
Maxy Gas cartridge
2a.
Code 483200
PRO//Max 400g cylinder
2b.
Code 483580
3. Trolley for bottles
4. Squares for blocking
O
pressure reducer Mignon
5.
2
with F.A.* Code 220500
Gas pressure reducer
6a.
Mignon with F.A.* Code
223515
Gas valve 7/16 with F.A.*
6b.
Code 201500
Handgrip with inserted
7.
F.A.*
Adjusting knob for O
8.
the torch
Adjusting knob for gas on
9.
the torch
10. Seal gasket
11a. O
hose with connect.
2
11b. Gas hose with connect.
12. 80lt nozzle
13. Lance
14. Lighter Code101000
Multipurpose wrench
15.
Code102000
Star with 4 nozzles
16.
Code110730.ESP
Brass welding rods
17.
Code101500.01
18. Goggles Code100000
3 spare gaskets kit
19.
Code B5910003.KIT
F.A.*= Fashback Arrestors
10
TURBO SET 90 TURBO SET 110
115050
131090.MP
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
on
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
TECHNICAL DATA
TURBO SET 90
Max. operating temp.
TURBO SET 110
Max. operating temp.
GAS CONSUMPTION
(normal regulation with a 80 lt nozzle):
End. of the O
cylinder
2
End. of the Maxy Gas cartridge
End. of the PRO//Max cylinder
1. GAS SUPPLY
All pressure vessels contained in the Turbo set 90 and 110 are
TPED approved in compliance with Directive 2010/35/EU and
specifically:
- Oxygen cylinder
- Maxy Gas cartridge
- PRO//Max cylinder
We recommend using the OXYTURBO cylinders and cartridges.
CAUTION: The oxygen and gas cylinders and gas cartridges of
the TURBO SET are non-refillable
CAUTIONS
• The use of other cylinders or cartridges may be dangerous
• Do not connect cylinders or cartridges before you have read
the instruction on them.
2. INSTALLATION
2.1 Inserting or changing cylinders or cartridges
- Put the two squares (4) on the trolley for bottles in
correspondence with the relevant cylinder or the gas cartridge.
- Insert the cylinder or the cartridge into their housing passing
the valves through the hole of the squares.
- Lock the brackets by manually tightening the wing nuts on the
screws (see fig.1).
- Make sure that the knobs on the Mignon reducers and on the
gas tap (5, 6a and 6b) and on the torch (8 and 9) are closed (for
Mignon: rotate towards the - symbol; for gas tap: turn towards
the + symbol).
- Manually tighten the oxygen and gas reducers and the gas
tap on the relative cylinders and cartridge without forcing
excessively, making sure there are no leaks (see 5.2).
CAUTIONS
• Cylinder and cartridge replacement and insertion operations
must always be performed in a well ventilated area,
preferably outdoors, away from flammable materials or
substances and incandescent heat sources (such as naked
flames, lit cigarettes, hot plates, etc.) and away from persons,
children and animals.
• Make sure the cylinder or cartridge is empty before replacing
it. Do not be fooled by the weight of the oxygen cylinder,
which is similar even when the cylinder is empty.
• Do not use the TURBO SET if there is evidence of damage to
cylinders, cartridges, reducers, taps, pipes (11a and 11b) or
handgrip.
• Do not use the TURBO SET if the sealing gaskets (10) damaged
or have been lost, replacing them if necessary with Code
B5910003.KIT.
GB
115050
3000 °C - 5432 °F
131090.MP
3100 °C - 5612 °F
92 g/h
0,30h
3,30 h
4,30 h
ISO 11118
EN 417
ISO 11118