3. INSTRUCTION FOR USE
Place before using lance and nozzle as in fig.2 and make sure the
nut (A) is blocked.
3.1 Switching on
- Make sure the adjusting knobs of the torch are closed (8 and 9).
- Open the oxygen pressure reducer Mignon (5) and the gas
Mignon/valve (6a and 6b).
- Open the adjusting knob for gas on the torch (9).
- Kindle using the special lighter (14) paying attention to keep
the flame stucked to the soldering nozzle. If the flame tends to
come off the nozzle, close a little the gas valve.
- Open the adjusting knob for oxygen on the torch (8) to obtain a
sparkling flame.
- Adjust the flame operating on the adjusting knobs to have a
dart with shape and dimensions like those of picture 2.
3.2 Switching off
- Close first the gas cartridge pressure reducer/valve (6a and 6b).
- Close the oxygen pressure reducer (5).
- Let the flame estinguish till the hoses are empty.
- Close the knobs of the nozzle (8 and 9).
CAUTIONS
• Always use the kit with cylinder and cartridge in vertical
position or the gas liquid phase could damage the hoses.
• Do not work in a narrow place.
• The TURBO SET must be used in a well ventilated area, away
from persons, children, animals and flammable materials or
substances or grease. Fire hazard!
• It is absolutely prohibited to grease any part of the kit.
• The TURBO SET should never be left unattended when
powered.
• Do not put down the lit torch.
• Work on a non-inflammable base.
• During welding works wear goggles (20) and gauntlets.
• Do not use grease or oil on the parts in contact with oxygen.
• Wear clothes suitable to the type of work to be accomplished
and do and do not wear clothes dirty with grease.
• Attention! Avoid breathing welding fumes.
• Replace immediatly the hoses with connections (11a and 11b)
in case of abrasions, deterioration or other imperfections.
• Avoid torsions, tears and overheatings of the hoses (11a and
11b).
• During use, TURBO SET parts can reach high temperatures:
do not touch.
• After switching off, let the pipes empty and let cool before
storing in a safe place, out of reach of children.
• it is dangerous to use damaged or incorrectly functioning
equipment.
• In case of gas delivery problems, check if there is gas in the
cylinder and in the cartridge (1 and 2). If so, the problem
could be resolved by cleaning the nozzle (see 5.4).
• Carrying out any operations other than those indicated in
this manual is STRICTLY PROHIBITED.
4. STORAGE
- If the TURBO SET is not to be used for a long period of time
or in case of transport by vehicle, unscrew the cylinders and
cartridges from the respective oxygen reducer and gas reducer/
tap. Avoiding the possibility of small and almost imperceptible
INSTRUCTIONS FOR USE AND MAINTENANCE
leaks. The cylinders and cartridges are equipped with
guaranteed tightness valves.
- Put away the TURBO SET in a protective packaging (if possible
in the original one) and keep it in a cool, dry and well ventilated
place.
CAUTIONS
For TURBO SETS with cylinders and cartridges inserted:
• Make the storage and the transport with the cylinders and
the cartridges in vertical position, NEVER lying.
• Protect from sunlight and from bad weather.
• Do not expose to temperatures higher than 50°C.
• Keep out of the reach of children.
5. MAINTENANCE
- Do not carry out maintenance or repairs, other than the
following.
- Use only original OXYTURBO spare parts and accessories.
- Spare parts are available from your retailer.
- In case of failures which cannot be repaired following these
instructions, take your TURBO SET back to the retailer.
5.1 Gas leaks
If your appliance leaks gas (gas smell) take it outdoors immediatly
to a well ventilated area, away from inflammable sources where
the seal can be checked (see 5.2).
5.2 Checking the seal
- To verify TURBO SET seal tightness, work outdoors and do
not use a flame but appropriate detectors (Gascontrol code
405000.EX) or soapy water.
- Spray the detector on the area to be checked.
- Gas leaks are detected by the formation of bubbles or foam.
5.3 Changing the gasket
- Remove the worn gasket from its seat (10).
- Insert the new gasket (19) in the housing by operating on the
edges with a flat screwdriver and taking care not to damage it.
5.4 Nozzle changing and cleaning
- Unscrew the nozzle (12) with the special wrench (15).
- Clean the nozzle blowing into the hole with compressed air.
- Screw the choosen nozzle (16) on the lance (13).
- Check the seal (see 5.2).
CAUTIONS
• Execute this intervention when the nozzle is cold.
• Do not use needles or pins to clean the nozzle, because any
damage you may cause to the appliance could make the
TURBO SET dangerous.
• If the blockage cannot be removed, substitute the nozzle.
6. INSTRUCTIONS FOR DISPOSAL
Dispose of the different kit components in accordance with local
regulations.
7. WARRANTY
- The product is guaranteed 3 years from the date of purchase.
- The warranty shall be void in the event of tampering or repairs
not authorised by the reseller.