1. Interrupt the air supply by closing the air inlet ball valve.
2. Disconnect the air inlet hose.
3. Open the discharge valve.
4. Wait until no more air passes through the discharge valve.
5. Unscrew the clamps and remove the lid.
6. Leave the discharge valve open, until the lid is put back in place.
10. Stopping and cleaning
1. Disconnect the pressure pot from the air compressor.
2. Despressurise the pressure pot by first turning wheel (1)
and then wheel (2).
3. Once the pressure pot is open, clean with the appropiate
thinner.
4. Close it again and perform the start-up rouline, re-
circulating the thinner through the hoses and guns, as many
times as necessary.
11. Maintenance
Before starting to work, verify the state of the product hoses and the connections of the elements
through which the product flows.
IN ORDER TO OBTAIN THE BEST POSSIBLE RESULTS, ALWAYS
USE ORIGINAL SAGOLA SPARES THAT GUARANTEE TOTAL
INTERCHANGEABILITY, SAFETY AND PERFECT OPERATION.
In order to carry out maintenance or repairs, first disconnect the unit from the compressed air
distribution network.
Never move the unit by dragging it by the hoses.
Do not apply excessive force or inadequate tools for maintaining and cleaning the unit. Some
repairs must be done with special tools on some occasions. In these cases, you must contact the
Customer Service of SAGOLA. Any handling of this product by non-authorised personnel would
render the warranty null and void.
The unit must be overhauled on a regular basis to check the status of its components and replace
these when they are not in perfect condition.
Do not use graphite greases as they dry out the joints, altering their operation.