3. INSTALLATION
To install the heat pump the hydraulic circuit and the power need to be connected.
3.1
Location
Standard NF C 15-100 recommends installing the heat pump at least 2.5 meters from the pool.
However, thanks to the differential circuit breaker, you can also choose to install it closer: Leave at
least 1.50 m in front of the heat pump and 30 cm of empty space to the sides and rear of the heat
pump.
≥ 1500
Do not place anything within 1.5m of the front of the heat pump.
Do not place any obstacles on top or in front of the device!
Do not use the heat pump as a step to access the spa.
Do not step on the heat pump.
Please respect the following rules when choosing the heat pump's installation location
1.
The location must be easily accessible for optimal operation and maintenance.
2.
The device must be installed on the ground, ideally on a level concrete slab. Ensure that
the ground is sufficiently stable and it can support the weight of the device.
3.
Check that there is enough air flow, that the air exhaust is not directed towards the
windows of neighbouring buildings, and that exhaust air cannot return to the intake. In
addition, ensure that there is enough space around the device to perform servicing and
maintenance.
4.
The device must not be installed in locations susceptible of being exposed to oil, flamma-
ble gas, corrosive agents, sulphur compounds, or near high frequency devices.
5.
Do not install the device near to roads or footpaths to avoid mud splattering.
6.
To avoid disturbing neighbours, make sure to install the device facing away from areas
sensitive to noise.
7.
Keep out of the reach of children insofar as possible.
10 |
EN
2.5m
SPA
OR
≥ 1500
Dimensions in mm
SPA
≥ 300
≥ 1500