3. INSTALLATION
3.2
Installation diagram
Filter
Wall plug
230V 16A 10mA
The filter located upstream of the heat pump must be regularly cleared so that the water in the
system is clean, thus avoiding the operational problems associated with dirt or clogging in the filter.
3.3
Hydraulic connection
Step 1
Screw the connectors for heat pump
3.4
Electrical connection
Pump's power plug integrates a 10mA differential
circuit breaker.
Regularly test the correct operation. In the event
of successive triggering or doubts contact the
after-sales service.
Before plugging in your heat pump, please
ensure the electrical socket is well protected,
properly grounded and protected from rain as
well as water projections.
Press the RESET button to start the ICE SPA
heat pump. The power indicator lights up in red:
the heat pump is on.
Control unit
Electric heater
Spa heater
control relay
Circulation
pump
Step 2
Connect the water inlet and outlet
Power indicator
TO THE SPA
Test
Reset
EN