2. Modify user settings
In the "Settings" menu, use the "User" button
on the input box
Cancels input and exits
Clears the last digit or symbol entered
List of user settings
N°
L0
Setting value of heating
L1
Temperature difference to start heating
L2
Temperature difference to stop heating
L3
Setting value of cooling
L4
Temperature difference to start cooling
L5
Temperature difference to stop cooling
L6
Setting value of auto mode
L7
Temperature difference to start for AUTO mode
L8
Circulation pump relay activation
L9
Water pump startup interval when the machine standby
L10
E-heater relay activation
L11
Ambient temperature to start the e-heater
L12
Temperature difference to start the e-heater automatically
L13
Temperature difference to start the e-heater manually
16 |
EN
4. USE
OF CONTROL PANEL
of the parameter you wish to modify.
Description
to access the user settings interface. Then click
The current value of each
parameter is displayed on this
screen in the corresponding
input boxes.
After pressing the input box, the
input screen appears.
Adjustment range
15°C~40°C
1°C~5°C
0°C~5°C
7°C~35°C
1°C~5°C
0°C~5°C
7°C~40°C
1°C~5°C
0 (deactivated)
/1 (activated)
30-90 min
0 (deactivated)
/1 (activated)
0°C~25°C
1°C~5°C
1°C~5°C
Enter the value of your
choice, then press "OK".
The chosen value must
be available within the
parameter setting range
(see below), otherwise
your choice will not be
saved.
Default V.
38°C
3°C
1°C
26°C
2°C
1°C
38°C
2°C
0
60 min
0
5°C
5°C
2°C