2.5. Protection

The charging station has several protections according to the model, as described below.
Q3
Q4
FS1MW / FW1MW (single phase with manual protections and
wattmeters)
For both cases:
Q1: Main switch 80 A
Q2, Q5: 30 mA type A residual current circuit breaker
Q3, Q4: Curve C thermal magnetic circuit breaker
Q2 and Q3 protect the left power socket
Q4 and Q5 protect the right power socket

2.6. EMC requirements

These charging stations have the necessary filtering elements to comply with EMC requirements for domestic
applications in order to prevent disturbances in other equipment outside the installation.
14
Q2
Q5
Q1
Q3
Q4
Q1
FS3MW / FW3MW (three phase with manual protections and
wattmeters)
ABW2011IQM01_A - Installation and Operation Manual
Unit description
Q2
Q5