Installation
STEP 3
INSTALL ANTI-TIP DEVICE
AWARNING
* All ranges can tip.
*« BURNS or other SERIOUS INJURIES
can result.
* INSTALL and CHECK the ANTI-TIP
bracket following these instructions.
To reduce the risk of tipping the range, the range must
e Attach the anti-tip brace onto the bottom of the
be secured by a properly installed anti-tip bracket. See
range in the recessed area. Install 2 hex screws
installation instructions shipped with the bracket
(provided) through the brace and into the range.
for complete details before attempting to install.
NOTE: This anti-tip device may be installed on the
To check if the bracket is installed and engaged properly,
OPPosite side of the range.
look underneath the range. The anti-tip bracket should
be inserted into the opening on the anti-tip brace on the
range. If the bracket arm misses the brace to the left or
right, or the bracket arm is not protruding through the
brace opening, the bracket must be reinstalled.
If the range is pulled from the wall for any reason, always
|
repeat this procedure to verify the range is properly
secured by the anti-tip bracket.
lf your range has no anti-tip bracket, call 1.800.626.8774
to receive one at no cost.
If the anti-tip device supplied with the range does not fit this
= « Measure and mark Dimension A (see table below)
i)
~~» Hex Screws
Anti-Tip Brace
Alternate Brace
Position
application, use the universal Anti-Tip Device WB2x7909.
from the left (or right) side of the installation
Read the AHAM Anti-Tip Safety Brochure packed with
location. If the countertop has an overhang,
the bracket
add that dimension to Dimension A.
e Place the anti-tip bracket against the floor and
Anti-Tip Parts Provided
back wall at the marked location. Mark screw holes
_
for fastening the bracket to the wall sole plate and
4 Wood Screws
Anti-Tip Bracket
the floor.
* Drill 1/8" pilot holes at a 20° angle.
e Secure the bracket to the wall and/or floor with
at least 2 wood screws (provided).
For Concrete or Cement Construction: You must
use appropriate fastening hardware (not provided).
3 Hex Head Screws
Anti-Tip Brace
Anti-Tip Bracket
Wall Sole Plate
AHAM Anti-Tip
Safety Brochure