Installation
Instructions
Convert Natural Gas to LP Gas Operation
Convert LP Gas to Natural Gas Operation
AWARN
| NG:
This conversion must
be performed by a qualified installer or gas supplier
in accordance with the manufacturer's instructions
and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified
agency performing this work assumes responsibility
for the conversion.
AWARN
| NG: The rangetop, as shipped from
the factory, is set for use with its intended gas. If you
wish to use your rangetop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.
A
WARNING:
The following adjustments
must be made before turning on the burner. Failure to
do so could result in serious injury. Be sure pressure
regulator has been converted as described in Step 2.
TOOLS YOU NEEDED FOR CONVERSION
[1 ORIFICE HOLDER
The range orifice holder is located behind the front access
panel at the bottom of the range. Remove the doorls }
(See instructions on page 10)
iu
and the screws on the top and
bottom of the front access
panel. Remove the front
access panel to access the
orifice holder.
Additional orifices may be
present. Use only the orifices
specified in the instructions for
your range or rangetop.
Front Access Cover
CONVERT THE REGULATOR(S)
Disconnect all electrical power at the main circuit
breaker or fuse box.
A. Shut off the gas supply by closing the manual
shut-off valve on the unit or by the wall.
B. Move the range out in order to access the rear of
the unit.
C. Remove the range back to access the regulator{s) -
(1) on 30" & 36" ranges and (2) on 48" ranges.
D
. Convert the pressure regulator(s):
¢ Unscrew the cap with plunger.
e Place your thumb against flat side of the plunger
and press down to snap the plunger out of the cap.
¢ Carefully look at the plunger to locate the NAT
or LP position.
¢ Turn the plunger over so that the desired gas is
showing
near the
bottom.
¢ Snap the
lunger
ack into
the cap.
¢ Screw the
cap back
onto the
regulator.
E. Reverse these steps to reassemble the pressure
regulator.
Gasket
Cap
NAT.
Position
Pressure Regulator
CHANGE BURNER ORIFICES
Burner Cap
INSTALLATION TIP: First remove all
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
A. Remove the burner grates,
burner caps and burner heads.
B. Loosen the top burner
Spark
orifices using a 7 mm
Igniter
nut driver. Use small
pliers to carefully lift out the orifices.
The main orifice is located
low in the center of the
burner, while the simmer
orifice is located higher
beside the center of the
burner.
Main
Orifice
Burner Base
<>
Simmer
A
of
Orifice
22