Appliance dimensions
Electrical Installation
The model stated on the front cover is rated at 120V AC,
60 Hz and uses a NEMA 5-15 plug to connect to a
dedicated 120 V microwave circuit.
Model
Connection
HMV3053U
NEMA 5-15
HMV3063U
NEMA 5-15
HMV3023U
NEMA 5-15
Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
15 Amp electrical supply with a fuse or a circuit
breaker
This product must be connected to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements of the National Electric Code or the
prevailing local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box
should be located in the area behind the appliance (see
section Cabinet Dimensions). The outlet box and supply
circuit should be installed by a qualified electrician and
conform to the National Electrical Code or the prevailing
local code.
The voltage used must be the same as specified on the
data plate of this appliance. Using a higher voltage is
dangerous and may result in a fire or appliance
damage. Using a lower voltage will cause slow cooking.
The manufacturer is not responsible for any damages
resulting from the use of the appliance with any voltage
other than specified.
Circuit
Requirements
120 V,
15 Amps
60 Hz
120 V,
15 Amps
60 Hz
120 V,
15 Amps
60 Hz
Note: Take into account that the front and rear
measurements of the appliance are not identical.
Power Requirements
The outlet must be properly grounded in accordance with
all applicable codes.
It can be installed anywhere inside the cabinet above the
appliance, within reach of the power cord (approx. 24 in).