Install batteries.
9a Install batteries into tray.
9b Connect the battery cable.
The lock will begin to initialize when the batteries are
L
connected. See Testing (pg 6).
9c Install tray into lock.
NOTICE
Do not crimp cables.
9d Install retainer.
10
Install levers.
10a To install interior lever, loosen set screw in lever using included
hex wrench. Push lever on. Tighten set screw firmly using
included hex wrench.
BAG 6
~15 in-lb
(2 Nm)
10b To install exterior lever, loosen set screw in lever using included
hex wrench. Ensure lever catch is recessed. Push lever on.
Tighten set screw firmly using included hex wrench.
BAG 6
~15 in-lb
(2 Nm)
Hand tighten only.
Repeated lever removal may lead to failure of the set screw.
Complete Testing (pg 6) now, before installing
L
covers.
11
Install covers.
11a Slide covers on.
11b Secure with screws.
BAG 6
Actual size
(black)
Screw
retained in
cover.
L See
BAG 5
for security screws.
5
NOTICE
Hand tighten only.
Pull spindle