Schlage XE360-T Serie Instrucciones Para La Instalación página 6

Cerradura tubular

Publicidad

Rehanding
a. Remove exterior assembly from door.
b. Loosen set screw.
c. Use hex wrench to press center of assembly to release the
lever.
Testing
Basic operation
1. Install the batteries. See step 9.
2. Allow the system to initialize.
3. Verify three (3) green blinks on the exterior assembly.
Note: System will automatically move to the secure
L
state.
4. Rotate the levers. Ensure operation is smooth.
DPS
1. Ensure the DPS is installed and connected correctly. See steps
2, 8 and 9.
2. The lock should be in factory (FDR) mode.
3. After power is applied and the system completes initialization
(3 green blinks), cancel advertising by rotating the interior lever
once.
4. Open the door, The interior and exterior indicators will blink
blue (1X) and beep (1X)
5. Close the door. The interior and exterior indicators will blink
blue (2X) and beep (2X).
d. Ensure lever catch is recessed, and then reinstall the lever,
facing the opposite direction. Lever will click when fully
installed. Tighten set screw.
Pull spindle
out to allow
lever catch to
fall down.
e. Reinstall all remaining parts.