Descargar Imprimir esta página

Schlage XE360-EW Serie Instrucciones Para La Instalación página 6

Publicidad

Rehanding
a. Remove exterior assembly from door.
b. Loosen set screw. Remove tailpiece assembly and spindle, as
shown.
c. Use hex wrench to press center of assembly to release the
lever.
Testing
See the User Guide for detailed
L
troubleshooting. See alle.co/
XE360UG.
Basic operation
1. Install the batteries. See step 7c.
2. Allow the system to initialize.
3. Verify three (3) green blinks on the exterior assembly.
4. Rotate the lever and press the push pad to ensure smooth
operation.
DPS
1. Ensure the DPS is installed and connected correctly. See step 2.
2. The lock should be in factory (FDR) mode.
3. After power is applied and the system completes initialization
(3 green blinks), cancel advertising by pressing and releasing
the exit device push pad one time.
d. Ensure lever catch is recessed, and then reinstall the lever,
facing the opposite direction. Lever will click when fully
installed. Tighten set screw.
e. Reinstall all remaining parts.
Repeated lever removal may lead to failure of the set screw.
Customer Service
1-877-671-7011
4. Open the door. The interior and exterior indicators will blink
blue (1X) and beep (1X).
5. Close the door. The interior and exterior indicators will blink
blue (2X) and beep (2X).
REX
1. Ensure the exit device pushpad switch is installed correctly and
connected to the exit trim.
See the exit device installation instructions for more
L
information.
2. Lock must be in FDR Mode.
3. After power is applied and the system completes initialization
(3 green blinks), cancel advertising by pressing and releasing
the exit device push pad one time.
4. Push in and hold the exit device push pad. The device will blink
amber (1X) and beep (1X).
5. Release the exit device push pad. The device will start
advertising (blue light on, beep 1X).
6
Pull spindle
out to allow
lever catch to
fall down.
NOTICE
www.allegion.com/us

Publicidad

loading