Maintenance Mantenimiento
Prefilter
Adsorption filter
Prefiltro
Filtro de
Préfiltre
adsorción
Filtro de
Filtre d'adsorption
entrada
Filtro de adsorção
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
gals./l
gals./l
1 x 2.4
2 x 4.5
1 x 9
2 x 17
conical
1 x 6.6
2 x 12
1 x 30
2 x 45
conical
24 h
H2O
20
Entretien Manutenção
Weight
Dimensions
Peso
Dimensiones
Poids
Dimensions
Peso
Medidas
lbs./kg
inch/mm
ø 9.5/240
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
19.8
9
ø 16/400
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1
55
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1
25
Filter replacement
Order Ref.
Referencia
This is necessary when
No. de comm.
- the water being discharged is too
No de
encomenda
cloudy (see 'Wastewater test')
- the filter is clogged (see 'Checking
of level indicator')
Note:
• Please observe the legal regulati-
ons in your country pertaining to
ÖWAMAT 6
the use and handling of filters, par-
ticularly with regard to keeping a
spare filter set.
XV KT06 AF2
• Only use OEKOSORB filter sets in
order to ensure operational reliabi-
lity. OEKOSORB filters can be
identified by their labelling and the
test seal.
• Do not use any other filters, since
the official approval of the de-
ÖWAMAT 8
vice would no longer be appli-
cable in such a case. Furthermo-
XV KT08 AF2
re, the correct functioning of the
ÖWAMAT (wastewater quality,
throughput capacity, filter service
life) could not be guaranteed.
• Soak new filter in water for 24 hours.
Procedure
1. Place new OEKOSORB filter set
near the unit. Keep the PE pak-
kaging of the new set for putting in
the old filters.
2. Shut off condensate inlet (see
"Cleaning of dirt collector" page
22)!
3. Open ÖWAMAT lid.
4. Remove overflow pipe by turning
(use gloves supplied).
5. Lift filter and allow it to drain.
Place filter into the PE bag and
close bag tightly.
6. Clean filter area and overflow.
7. Insert the new filter slowly, pu-
shing it downwards by hand only.
8. Put back the overflow pipe and the
lid.
9. Open condensate inlet.
10. Ensure correct disposal of the
fouled filter.
english