Problem
IP address cannot be pinged.
Occasional interruptions in
WLAN data communication.
10
Disposal
Components and auxiliary materials of the product pose risks to the health and the environment. The tool contains com-
ponents that can be recycled as well as components that must be specially disposed of.
► Separate the components of the packing and segregate the different materials before disposing of them.
► Follow the locally applicable regulations.
Observe generally valid disposal guidelines such as, in Germany, the Electrical and Electronic Equipment
Act (ElektroG) and the Battery Act (BattG).
► Dispose of waste battery packs.
► Return the battery to your company collection facility or to Sales & Service Center.
► Do not dispose of the batterie packs in the household waste or throw them into fire or water.
Apex Tool Group
Possible cause
IP address already exists in
the network. In this case, the
tool will not establish a connec-
tion.
Distance between the access
point and the tool is too great.
Excessive data traffic on
WLAN network.
P2506BA | REV D l 2023-10
Measure
► Check the physical connection (RSSI values):
>
► Check the assigned IP address.
1.
Check signal strength at tool in the submenu Sig-
nal Strength:
>
2.
If necessary, reduce the distance between the
access point and the tool.
Reduce data traffic on WLAN network.
1.
On the Basic control screen, increase the Trigger:
Navigator > Basic Application Builder > Trigger
Torque.
2.
Disable the torque graph data transmission on
Navigator > Advanced > Controller > General >
Trace Recording. For this, select the entry Rec-
ord in the column Off.