GAS UTILISATION primetech stove
This stove is intended for use with Primus gas Propane/Isobutane/
Butane in cartridges with designation 2202xx, 2206xx, 2207xx. (Red
Power Gas, green Summer Gas or brown Winter Gas).
Gas consumption is 2,6 kW / 198 g/h (CE). 6050 BTU/h (ANSI).
The diameter of the bore in the nozzle of the stove's burner is 0.35 mm.
This gas appliance conforms to the provisions of EN521/ANSI Z21.72-16/CSA 11.2-16.
CHECKING THE STOVE.
there is a leak on your appliance (smell of gas), take it outside immedi-
ately into a well ventilated flame free location where the leak may be
detected and stopped. If you wish to check for leaks on your appliance,
do it outside. Do not try to detect leaks using a flame, use soapy water.
Contact Primus or your local dealership for replacement parts. You will
find contact information on the back page of this instruction booklet.
1.
Smell or listen for gas leaks from the gas cartridge.
check by putting some soapy water on the connection to the gas cartridge. If you see any
bubbles, there is a gas leak - DO NOT LIGHT the stove!
2.
The valve handle
connecting the gas cartridge.
on the stove must be closed (turn clockwise to close) before
important:
If you are not certain, you can