Soft Start Speed Level Setting
The speed of soft start can be set.
The duration of soft start should be set
in " u1 Soft Start & Soft Snug Time
Setting".
P. 32
• Because of the structure of the motor,
it requires some time to increase the
speed of the soft start to the normal
speed.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "u2" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Soft start speed level (Rotations/minute)
Display
EYADA218XC
EYADA212XC
EYADA407XC
* Relative to the maximum
number of rotations
Display
EYADA218XC
EYADA212XC
EYADA407XC
* Relative to the maximum
number of rotations
• The values (numbers of rotations) are only guidelines.
EYADA_EU.indb
EYADA_EU.indb
33
33
P. 22
Level1
Level2
450
600
300
400
160
220
About 25%
Level6
Level7
1200
1350
800
900
430
490
About 75%
When it is set to "04"
During the time set
in soft start, a screw
is fastened slowly
at about 50% of the
maximum speed.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "10".
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
Level3
Level4
750
900
500
600
270
330
About 50%
Level8
Level9
1500
1650
1000
1100
540
600
P. 22
Level5
1050
700
380
Level10
1800
1200
650
About 100%