Operating functions
Switching the pump on/off
Proceed as follows
Increasing or decreasing rotation speed
Proceed as follows
Displaying current status values
Proceed as follows
32
Press the button briefly to turn the
pump on or off.
Press the desired button several
times or push continually in order to
change the rotation speed in per-
cent.
Press the button briefly to select the
next mode.
Information
When the pump is switched off, the display shows
"OFF".
Information
• Adjustable range: 1 % ... 100 %
• Increment: 1 %
• Adjustment is only possible in "Speed / %" or
"Power / W" modes.
• The adjusted value is immediately adopted.
• By pressing a button the controller automatically
switches to "Speed / %" mode.
After 15 s without operation the controller automati-
cally switches to "Power / W"mode.
Information
"Runtime / h" mode
• Displays the total operating hours of the pump
• Displays up to 9999 operating hours: 0 to 9999
− Displayed increments: 1 hour
• Displays from 10000 to 99900 operating hours:
100H to 999H
− Displayed increments: 100 hours
− Example: 022H = 22 × 100 = 2200 operating hours
"Power / W" mode
• Displays the current power consumption of the
pump in watts
− Tolerance: ±5 % of the max. power consumption.
(→ Technical data)
"RPM" mode
• Displays the current speed of the pump in revolu-
tions per minute
"Speed / %" mode
• Displays the current speed in percentage
− Display range: 1 to 100
After 15 s without operation the controller automati-
cally switches to "Power / W"mode.