Error messages
The error message automatically disappears after the error has been corrected.
Error message
Er1
Er2
Er3
Er4
Er5
Er6
Er7
Er8
Cause
No pump connected or connection to
pump is faulty
Communication error between controller
and pump
Excess temperature
Overcurrent
Pump blocked
Pump has run dry
Overvoltage
Undervoltage
Remedy
• Check that cable is connected correctly
to pump
• Connect the pump to the controller
• Check that cable is connected correctly
to pump.
• Connect the pump to the controller
• Check that impeller unit moves freely
− If the impeller unit is sluggish, the
pump is requiring too much power
• The ambient temperature is too high
Check that impeller unit moves freely
• If the impeller unit is sluggish, the
pump is requiring too much power
Check pump and remove obstacle
• Submerge pump in water
• For dry installation ensure adequate
water supply
Connect the pump to the correct mains
voltage
• The unit is not suitable for use with the
existing mains voltage range
• Keep extension cable to the pump as
short as possible.
− The voltage to the pump is too low
due to the voltage drop in long ca-
bles.
• Use extension cable to the pump with
greater conductor cross-section
− The voltage to the pump is too low
due to the voltage drop in cables with
too small of a conductor cross-sec-
tion.
EN